Detector area expansion at iNSE neutron spin echo spectrometer

โœ Scribed by N.L. Yamada; H. Endo; N. Osaka; Y. Kawabata; M. Nagao; T. Takeda; H. Seto; M. Shibayama


Publisher
Elsevier Science
Year
2009
Tongue
English
Weight
360 KB
Volume
404
Category
Article
ISSN
0921-4526

No coin nor oath required. For personal study only.

โœฆ Synopsis


Expansion of a detection area is an effective method to increase the measurement efficiency of a neutron spin echo (NSE) spectrometer as well as other spectrometers. For this purpose, we installed a new p=2 spin flipper and Fresnel coil of iNSE spectrometer at JRR-3, Tokai, Japan, for wide-area data acquisition. In this study, we propose a data reduction method to correct the phase inhomogeneity due to the path difference of neutrons on the large detection area. This method can convert many NSE signals at small areas to one NSE signal at a large area with taking the phase offset due to the phase inhomogeneity into account. The measurement efficiency increased by approximately one order of magnitude as a result of the detection area expansion.


๐Ÿ“œ SIMILAR VOLUMES


Improvement of neutron spin echo spectro
โœ T. Takeda; H. Seto; Y. Kawabata; D. Okuhara; T. Krist; C.M.E. Zeyen; I.S. Anders ๐Ÿ“‚ Article ๐Ÿ“… 1999 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 84 KB

We have improved a neutron spin echo spectrometer at the C2-2 port of JRR-3M, JAERI. The new double reflection supermirror monochromators with the wavelength l 5.9 A หš(Dl/l 15%) and l 7.14 A หš(Dl/l 18%) increased the polarized neutron flux at the sample position about three times more than the old m