𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Detection and characterization of focal hepatic lesions: Mangafodipir vs. Superparamagnetic iron oxide-enhanced magnetic resonance imaging

✍ Scribed by Myeong-Jin Kim; Joo Hee Kim; Joon Seok Lim; Young Taik Oh; Jae-Joon Chung; Jin Sup Choi; Woo Jung Lee; Ki Whang Kim


Publisher
John Wiley and Sons
Year
2004
Tongue
English
Weight
598 KB
Volume
20
Category
Article
ISSN
1053-1807

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Purpose

To compare the mangafodipir‐enhanced magnetic resonance (MR) and superparamagnetic iron oxide (SPIO)‐enhanced images for their ability to detect and characterize focal hepatic lesions.

Materials and Methods

Unenhanced, mangafodipir‐enhanced, and SPIO‐enhanced hepatic MR images obtained from 64 patients were analyzed. A total of 121 hepatic lesions were included: 66 hepatocellular carcinomas (HCCs), 26 metastases, 14 hemangiomas, 5 cysts, 3 cholangiocarcinomas, 4 focal nodular hyperplasias (FNHs), 2 abscesses, and 1 adenoma. Two radiologists independently reviewed the two sets of images in a random order: 1) the unenhanced and mangafodipir‐enhanced images (the mangafodipir set) and 2) the unenhanced and SPIO‐enhanced images (the SPIO set). This study compared the accuracy of lesion detection, the ability to distinguish between a benign and malignant lesion, and the ability to distinguish between the hepatocellular and nonhepatocellular origins of the lesions using the areas (Az) under the receiver operating characteristic (ROC) curve.

Results

The overall accuracy for detecting focal lesions was significantly higher (P < 0.05) with the SPIO set (Az = 0.846 and 0.871 for readers 1 and 2, respectively) than with the mangafodipir set (Az = 0.716 and 0.766). Most of the lesions detected only with the SPIO‐enhanced MR images by the readers were small HCCs. For lesions larger than 15 mm, the sensitivities of the two contrast enhancement techniques were similar for both readers. The accuracy of the mangafodipir and SPIO sets in distinguishingbetween benign and malignant lesions was comparable. The accuracy for distinguishing between the hepatocellular and nonhepatocellular origins of the lesions was significantly higher (P < 0.05) using the mangafodipir set (Az = 0.897 and 0.946) than using the SPIO set (Az = 0.741 and 0.833).

Conclusion

SPIO‐ and mangafodipir‐enhanced images were comparable for detection of focal hepatic lesions other than small HCCs, which were better detected on the SPIO‐enhanced images. Mangafodipir‐enhanced images are likely better than the SPIO‐enhanced images for distinguishing between focal liver lesions with a hepatocellular or nonhepatocellular origin. J. Magn. Reson. Imaging 2004;20:612–621. © 2004 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Mangafodipir trisodium-enhanced MRI for
✍ Jae-Joon Chung; Myeong-Jin Kim; Ki Whang Kim 📂 Article 📅 2006 🏛 John Wiley and Sons 🌐 English ⚖ 349 KB 👁 1 views

## Abstract ## Purpose To investigate the usefulness of early and delayed hepatic MRI after mangafodipir trisodium (Mn‐DPDP) administration for the detection and characterization of focal hepatic lesions. ## Materials and Methods Forty‐five patients (31 males and 14 females, mean age = 61 years)

Superparamagnetic iron oxide: Detection
✍ Stephan H. Duda; Michael Laniado; Andreas F. Kopp; Eckart Grönewäller; Klaus P. 📂 Article 📅 1994 🏛 John Wiley and Sons 🌐 English ⚖ 829 KB

## Abstract AMI‐25 was evaluated at 1.5 T as a superparamagnetic iron oxide contrast agent for the liver. Sixteen patients with up to five suspected focal liver lesions were examined with T1‐, proton‐density—, and T2‐weighted spin‐echo sequences before and after intravenous administration of AMI‐25

Evaluating the severity of nonalcoholic
✍ Kengo Tomita; Akihiro Tanimoto; Rie Irie; Masahiro Kikuchi; Hirokazu Yokoyama; T 📂 Article 📅 2008 🏛 John Wiley and Sons 🌐 English ⚖ 342 KB

## Abstract ## Purpose To evaluate the utility of noninvasive assessment of human nonalcoholic fatty liver disease (NAFLD) patients using superparamagnetic iron oxide (SPIO)‐enhanced MRI. ## Materials and Methods Nineteen NAFLD patients underwent SPIO‐enhanced MRI. The values of τ, a time consta

Superparamagnetic iron oxide (SPIO)-enha
✍ Sook Namkung; Christoph J. Zech; Thomas Helmberger; Maximilian F. Reiser; Stefan 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 692 KB

## Abstract ## Purpose To evaluate the efficacy of ferucarbotran in T2‐weighted (T2W) fast spin‐echo (FSE) and T2\*W gradient‐echo (GRE) sequences for characterizing focal liver lesions. ## Materials and Methods In 68 patients, 46 malignant and 22 benign focal liver lesions were evaluated. Preco

Diagnosis of colorectal hepatic metastas
✍ Ali Muhi; Tomoaki Ichikawa; Utaroh Motosugi; Hironobu Sou; Hiroto Nakajima; Kats 📂 Article 📅 2010 🏛 John Wiley and Sons 🌐 English ⚖ 540 KB

## Abstract ## Purpose To compare the diagnostic accuracy of contrast‐enhanced ultrasonography (CE‐US), contrast‐enhanced CT (CE‐CT), and superparamagnetic iron oxide‐enhanced MRI (SPIO‐MRI) with diffusion‐weighted imaging (DWI) in the evaluation of colorectal hepatic metastases. ## Materials and

Improved focal liver lesion detection: C
✍ Kenneth Coenegrachts; Hans Orlent; Leon ter Beek; Marc Haspeslagh; Shandra Bipat 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 160 KB

## Abstract ## Purpose To prospectively compare single‐shot spin‐echo echo‐planar imaging (SSSE‐EPI) using b = 0, 10, 150, and 400 seconds/mm^2^ with standard MRI techniques after intravenous super paramagnetic iron oxide (SPIO) in the detection and characterization of focal liver lesions with foc