๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Detecting errors in micro and trace analysis by using statistics

โœ Scribed by K. Heydorn


Publisher
Elsevier Science
Year
1993
Tongue
English
Weight
476 KB
Volume
283
Category
Article
ISSN
0003-2670

No coin nor oath required. For personal study only.

โœฆ Synopsis


By assigning a standard deviation to each step in an analytical method it is possible to predict the standard deviation of each analytical result obtained by this method. If the actual variability of replicate analytical results agrees with the expected, the analytical method is said to be in statistical control. Significant deviations between analytical results from different laboratories reveal the presence of systematic errors, and agreement between different laboratories indicate the absence of systematic errors. This statistical approach, referred to as the analysis of precision, was applied to results for chlorine in freshwater from BCR certification analyses by highly competent analytical laboratories in the EC. Titration showed systematic errors of several percent, while radiochemical neutron activation analysis produced results without detectable bias.


๐Ÿ“œ SIMILAR VOLUMES


Detecting proportional and constant bias
โœ ร€ngel Martฤฑฬnez; F.Javier del Rฤฑฬo; Jordi Riu; F.Xavier Rius ๐Ÿ“‚ Article ๐Ÿ“… 1999 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 287 KB

Constant or proportional bias in method comparison studies using linear regression can be detected by an individual test on the intercept or the slope of the line regressed from the results of the two methods to be compared. Since there are errors ลฝ in both methods, a regression technique that takes

Trace Levels Determination of Ammonium b
โœ Henrique L. Braz; Dรฉbora T. Ito; Josรฉ A. Fracassi daโ€…Silva; Claudimir L. doโ€…Lago ๐Ÿ“‚ Article ๐Ÿ“… 2011 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 277 KB ๐Ÿ‘ 1 views

## Abstract A sensitive analytical method based on gasโ€diffusion flow injection system for ammonium ion determination at trace levels with capacitively coupled contactless conductivity detection (C^4^D) is described. The effects of the chemical composition of the acceptor stream, operating frequenc

Trace analysis of hetero aromatic compou
โœ Johansen, Sys Stybe ;Pawliszyn, Janusz ๐Ÿ“‚ Article ๐Ÿ“… 1996 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 546 KB

## Abstract By using Solid Phase Microโ€Extraction (SPME) and Capillary Gas Chromatography (CGC) a method was developed to analyze hetero aromatic compounds (NSO) in water. Compounds with nitrogen, sulfur, or oxygen in the aromatic ring system are found in creosotecontaminated groundwater. NSO are h