The diffusion time dependence of the brain water diffusion tensor provides information regarding diffusion restriction and hindrance but has received little attention, primarily due to limitations in gradient amplitude available on clinical MRI systems, required to achieve short diffusion times. Usi
Dependence on diffusion time of apparent diffusion tensor of ex vivo calf tongue and heart
β Scribed by Sungheon Kim; Gloria Chi-Fishman; Alan S. Barnett; Carlo Pierpaoli
- Book ID
- 102956203
- Publisher
- John Wiley and Sons
- Year
- 2005
- Tongue
- English
- Weight
- 549 KB
- Volume
- 54
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
β¦ Synopsis
Abstract
The time dependence of the apparent diffusion tensor of ex vivo calf heart and tongue was measured for diffusion times (Ο~d~) between 32 and 810 ms. The results showed evidence of restricted diffusion in the muscle tissues of both organs. In regions where the myofibers are parallel, the largest eigenvalue (Ξ»~1~) of the diffusion tensor remained the same for all diffusion times measured, while the other eigenvalues (Ξ»~2~, Ξ»~3~) decreased by 29β36% between Ο~d~ = 32 ms and Ο~d~ = 400 ms. In regions where the fibers cross, the Ξ»~1~ also changed, decreasing by 17% between Ο~d~ = 32 ms and Ο~d~ = 400 ms. The restricting compartment size and volume fraction were effectively estimated by fitting the time courses of the eigenvalues to a model consisting of a nonrestricted compartment and a cylindrically restricted compartment. To our knowledge, this study is the first demonstrating diffusion time dependence of measured water diffusion tensor in muscular tissue. With improvement in scanning technology, future studies may permit noninvasive, in vivo detection of changes in muscle myoarchitecture due to disease, treatment, and exercise. Magn Reson Med, 2005. Published 2005 WileyβLiss, Inc.
π SIMILAR VOLUMES
## Abstract Diffusion tensor imaging (DTI) is an emerging noninvasive method for evaluating tissue microstructure, but is highly susceptible to __in vivo__ motion artifact. __Ex vivo__ experiments on fixed tissues are needed to improve DTI techniques, which require fixed tissue specimens. Several e
## Abstract We used a numerical simulation of water selfβdiffusion among permeable cylinders to predict the dependence of MRβbased apparent diffusion coefficients in white matter on axonal separation, barrier permeability, and diffusion time (T). The transverse apparent diffusion coefficient (tADC)
To perform serial in-vivo diffusion tensor MRI (DTI) and tractography of the mouse heart and characterize the impact of ischemia on myocardial microstructure.