โœฆ Synopsis


Abstract

Ultraโ€high molecular weight polyethylene components for total joint replacement chemically degrade before and after implantation, and the degradation is associated with an increase in density. The goal of this study was to determine the average rate of density change in these components following sterilization by gamma radiation in air as a function of shelf age and implantation time. Using the density gradient column method, density profiles were obtained through the thickness from loaded and unloded regions of 10 retrieved Insallโ€Burstein/Posteriorโ€Stabilized II tibial components and one operatingโ€room inventory component for which the initial density profile and patient history (if applicable) were known. The average density of the components increased at a constant rate of 0.000186 g/cc/month during the first 50 months after sterilization (r^2^ = 0.54) but was not significantly affected by loading (p > 0.05). The quantitative degradation rates may be useful to help verify kinetic models to predict bulk degradative changes on the basis of microstructural and chemical processes. This research also suggests the hypothesis that degradation of ultraโ€high molecular weight polyethylene can be modeled in terms of changes in bulk or average properties.


๐Ÿ“œ SIMILAR VOLUMES


Contact pressure dependence of wear rate
โœ Rostoker, W. ;Galante, J. O. ๐Ÿ“‚ Article ๐Ÿ“… 1979 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 355 KB

## Abstract Wear rates of orthopaedic polyethylene in 37ยฐC water are not very contact stress dependent below 1000 psi (6.9 MPa) but above that level they accelerate substantially. The pressure dependence overall follows an exponential function. Creep in the contact pressure range of 3โ€“17 MPa and ab

Evaluation of sequentially crosslinked u
โœ M. L. Morrison; S. Jani ๐Ÿ“‚ Article ๐Ÿ“… 2008 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 404 KB

## Abstract This study was undertaken to investigate the effect of crosslinking ultraโ€high molecular weight polyethylene (UHMWPE) in a sequential manner to the final desired dose and to compare the results to singleโ€dose crosslinking. To verify these results, an explanted, commercially available, s