β¦ Synopsis
Abstract
A highβspeed vacuum circuit breaker (HSVCB) has been investigated. HSVCB makes highβfrequency current superimposed on a fault current so that the current is forced to be zero and is interrupted. Its interruption performance is considered to be dependent on the rate of change of the current (di/dt). As a fundamental research, we investigated the di/dtβ dv/dt characteristics and the insulation recovery characteristic after interrupting the counterβpulse current for various contact materials of AgWC, CuW, and CuCr. The results revealed that the case where the gap length is larger is better in a current interruption performance. Moreover, it was found that di/dt is not dependent on the insulation recovery characteristics, but the magnitude of interruption current is of great influence. Β© 2007 Wiley Periodicals, Inc. Electr Eng Jpn, 161(1): 17β 25, 2007; Published online in Wiley InterScience (www.interscience.wiley.com). DOI 10.1002/eej.20362