Cryogenic temperature near-threshold fatigue crack growth rate data for JBK-75 stainless steel
โ Scribed by P.K. Liaw; W.A. Logsdon; M.H. Attaar
- Publisher
- Elsevier Science
- Year
- 1983
- Tongue
- English
- Weight
- 303 KB
- Volume
- 23
- Category
- Article
- ISSN
- 0011-2275
No coin nor oath required. For personal study only.
โฆ Synopsis
An important structural component of the Westinghouse Large Coil Programme superconducting magnet is the JBK-75 (modified A-286) stainless steel conductor sheath. Because the presence of pre-existing cracl(s or flaws in the conductor sheath is a potential possibility, the structural reliability of the conductor sheath would be enhanced ff a threshold level of stress intensity range (AKth) was established below which fatigue crack growth would not occur. Consequently, near-threshold fatigue growth rate data were generated at two load ratios on JBK-75 stainless steel at room and cryogenic temperatures. No load ratio effect on near-threshold fatigue crack growth rate was observed at cryogenic temperatures.