An on-line, real-time, interactive computerized ECG monitoring system has been developed that detects and quantifies heart rate, ventricular premature contractions, and atria1 premature contractions. Over several months more than Mpatients were monitored by this computer system. Five-hundred waves o
Corrosion rate monitoring with computerized systems
β Scribed by Dr. G. Rocchini
- Publisher
- John Wiley and Sons
- Year
- 1995
- Tongue
- German
- Weight
- 932 KB
- Volume
- 46
- Category
- Article
- ISSN
- 0947-5117
No coin nor oath required. For personal study only.
β¦ Synopsis
Abstract
Some observations concerning the aims of corrosion rate monitoring, the choice of the electrochemical parameter, the opportunity of optimising the measurement technique and the usefulness of developing specific software for computerised systems are made. The basic concepts for the evaluation of the mass loss of metals or alloys are introduced and some mathematical formulas of the method of successive approximations are given.
A short description of the SOFTCORβDCβPHTS code is given, Which concerns its improvements and the most important points and stresses the significant differences between this program and commercial software and the potentialities of the present method.
The experimental applications, concerning the behaviours of Armco iron and SA 182 grades F11 and F22 carbon steels in inhibited 5% by weight HCl solutions at 75Β°C and SA 106 grade B carbon steel in solutions containing 100 gl^β1^ of EDTA at 100Β°C and different pH values, have demonstrated the existence of a discrepancy between direct and electrochemical determinations of the corrosion rate. The value of the electrochemical determination of the corrosion rate, obtained through potentiostatic measurements with a polarization time of 1 s, was higher than the mean value of the direct evaluation from weight loss data. The present results show that the electrochemical technique cannot reproduce the true behaviour of a corrosion process. However, the SOFTCORβDCβPHTS program is very useful to deal with the problem of monitoring the corrosion rate of metals in acid media and to process experimental data without the intervention of an operator.
Finally, it has been experimentally demonstrated that the determination of the polarization resistance depends on the technique adopted for performing polarization measurements.
π SIMILAR VOLUMES
## Abstract The linear polarization method of corrosion rate determination has been investigated on the basis of the equation of __Stern__ and __Geary__. It has been demonstrated that use of an average value for the parameter B does not lead to accurate results. A procedure has been suggested for r
## Abstract The definition and meaning of the polarization resistance, after __BonhΓΆffer__ and __Jena__, are discussed, and its relationship with the corrosion rate is given. The basic mathematical ideas suitable to introduce the method of calibration charts, first proposed by __Skold__ and __Larso
An automated microcomputer system for monitoring heart rate and systolic time intervals (STI)-preejection period (PEP), left ventricular ejection time (LVET), and PEP/LVETwas implemented. The system, employing esophageal accelerometry, is economical and simple to operate. Being light and compact, it