Electrochemical corrosion behavior of electroless Ni-P coating in NaCl and H 2 SO 4 solutions were studied by potentiodynamic polarization curves and electrochemical impedance spectra techniques, as well as the corrosion morphology was characterized. The results indicate that electroless Ni-P coatin
Corrosion characteristics of electroless Ni–P coating in sulfur-bearing solution
✍ Scribed by Y. H. Wu; T. M. Liu; S. X. Luo
- Publisher
- John Wiley and Sons
- Year
- 2009
- Tongue
- German
- Weight
- 351 KB
- Volume
- 60
- Category
- Article
- ISSN
- 0947-5117
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
The corrosion behaviors of electroless Ni–P coatings deposited on carbon steel in sulfur‐bearing solutions were investigated by weight gain test and scanning electron microscopy. The results indicate that the corrosion rate of electroless Ni–P coating was directly related to the sulfur content, immersion time, and test temperature. The corrosion rate increased with the prolonged immersion time. Increasing the temperature can markedly increase the corrosion rate of electroless Ni–P coating. The electroless Ni–P coating had a better corrosion resistance than 316L stainless steel against Cl^−^ corrosion in sulfur‐bearing solution.
📜 SIMILAR VOLUMES
## Abstract Electroless Ni–PTFE–P coatings have been successfully deposited on the surface of mild steel shaft from plating baths containing various concentrations of rare earth metal cerium (RE Ce). Surface morphology, Ce fraction, and thickness of the coatings were characterized by scanning elect
## Abstract Electroless Ni‐P‐ZrO~2~ and Ni‐P coatings on AZ91D magnesium alloy were prepared, and their corrosion protection properties were compared in this paper. The potentiodynamic curves and electrochemical impedance spectroscopy (EIS) of the coated magnesium alloy in 3.5% NaCl solution showed
## Abstract 76Ni‐24P amorphous alloys have been electrodeposited from solutions containing sodium lauryl sulphate (SLS) and triton‐X 100 (TX‐100) to improve the surface quality of the specimens. Corrosion behaviour of electrodeposited amorphous alloys in sulphate and chloride solutions at 25°C has
## Abstract 76Ni‐24P amorphous alloys have been electrodeposited from solutions containing sodium lauryl sulphate (SLS) and triton‐X 100 (TX‐100) to improve the surface quality of the specimens. Corrosion behaviour of electrodeposited amorphous alloys in sulphate and chloride solutions at 25°C has
The paper discusses cement production in using a vertical kiln. We caution the authors that some recent work by us has shown that high sulfur contents of clinker made in a rotary kiln may lead to delayed ettringite formation (DEF) if the sulfate is not readily soluble. No standard tests of cement, i