Internal fixation of the distal radius
✍
C. P. Rader; C. Räuber; K. E. Rehm; J. Koebke
📂
Article
📅
1995
🏛
Springer
🌐
English
⚖ 307 KB
In a comparative, experimental examination of 60 human Cadaver radii, the stability of various, widely used internal fixation procedures of a distal radius fracture loco typico using a dorsal wedge was determined. The use of 2.5-mm Kirschner wires (K-wires) delivered a 10% greater stability than 1.8