𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Coronary blood flow velocities during rotational atherectomy

✍ Scribed by Kumar, Krishna ;Dorros, Gerald ;Dufek, Christine ;Mathiak, Lynne


Publisher
John Wiley and Sons
Year
1997
Tongue
English
Weight
63 KB
Volume
41
Category
Article
ISSN
0098-6569

No coin nor oath required. For personal study only.

✦ Synopsis


This study was designed to evaluate the alterations in doppler derived coronary blood flow velocities and flow reserve following rotational ablation.

Changes in doppler derived coronary blood flow velocity variables have been valuable in assessing the physiological outcome following coronary balloon angioplasty. Rotational ablation's mechanism of plaque removal could alter distal vascular bed characteristics, and, as a result, intracoronary blood flow velocities and the coronary flow reserve.

A 12-MHz doppler guidewire recorded intracoronary phasic velocities and coronary flow reserve (as assessed by the hyperemic response to adenosine [12-18 mcg intracoronary]) in 28 patients, before and after rotational ablation of 30 lesions. Adjunctive balloon angioplasty was performed in 27 of 28 patients (96%).

Rotational ablation and adjunctive balloon angioplasty successfully reduced the lesion diameter (87 6 9% to 14 6 11%; P F 0.001). A significant increase in the mean distal average peak velocity (25 6 13 cm/sec, before; 47 6 22 cm/sec, after; P F 0.001), and decrease in the proximal to distal average peak velocity ratio, (2.1 6 1.3; to 1.2 6 0.4; P 5 0.002) was recorded. The mean distal diastolic to systolic velocity ratio (before, 1.4 6 0.7; after, 1.6 6 0.8; P 5 0.44) and the coronary flow reserve (before, 1.6 6 0.6; after, 1.5 6 0.5; P 5 0.34) did not increase despite increases in distal velocities, following successful intervention. Doppler derived distal coronary blood flow velocities increased following rotational ablation and adjunctive balloon angioplasty, with resolution of transstenotic velocity gradient. Changes in distal phasic velocity pattern and coronary flow reserve, immediately after the intervention, were not useful in the assessment of the functional outcome and may be related to abnormalities in distal vascular bed vasoreactivity produced by rotational ablation.


πŸ“œ SIMILAR VOLUMES


Fracture of coronary guidewire during ro
✍ Woodfield, Scott L. ;Lopez, Alejandro ;Heuser, Richard R. πŸ“‚ Article πŸ“… 1998 πŸ› John Wiley and Sons 🌐 English βš– 173 KB πŸ‘ 1 views

We present the case of a calcified right coronary artery lesion with a 90-degree exit angle. Attempts at rotational atherectomy led to wire transection and vessel wall perforation necessitating emergent pericardiocentesis and bypass surgery. We review the literature on complications of rotational at

Assessment of collateral flow during bal
✍ Piek, Jan J. ;Koch, Karel T. H. ;van Liebergen, Rob ;Peters, Ron J. G. ;David, G πŸ“‚ Article πŸ“… 1995 πŸ› John Wiley and Sons 🌐 English βš– 606 KB

## Abstract Coronary blood flow velocity analysis of the contralateral and of the ipsilateral artery can be used to assess collateral flow during controlled balloon coronary occlusion. Coronary blood flow velocity assessment in combination with measurement of aortic pressure and coronary wedge pres

Bail-out stenting for flow limiting diss
✍ Levin, Thomas N. ;Carroll, John D. ;Feldman, Ted πŸ“‚ Article πŸ“… 1996 πŸ› John Wiley and Sons 🌐 English βš– 541 KB

Flow limiting dissection may occur after rotatlonal atherectomy and require urgent management. Important questions about the safety and effectiveness of bail-out stenting In this setting remain to be answered. We have observed that emergent stenting after rotational atherectomy can be accomplished s

Dislocation of the rotating cutter durin
✍ Bauriedel, Gerhard ;Schluckebier, Sven ;Welsch, Ulrich ;Werdan, Karl ;HΓΆfling, B πŸ“‚ Article πŸ“… 1995 πŸ› John Wiley and Sons 🌐 English βš– 529 KB

Directional coronary atherectomy (DCA) has received increased attention, especially as a bail-out procedure after failed balloon angioplasty. However, this technique may also be burdened by severe pitfalls. We report a patient with a balloon-resistant left coronary artery lesion subsequently treated