𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Coronary artery pseudo-occlusion associated with the use of an active hemoperfusion system during ptca

✍ Scribed by Grill, Howard P. ;Dowger, Barbara A. ;Brinker, Jeffrey A.


Publisher
John Wiley and Sons
Year
1991
Tongue
English
Weight
369 KB
Volume
24
Category
Article
ISSN
0098-6569

No coin nor oath required. For personal study only.

✦ Synopsis


We describe the phenomenon of coronary artery "pseudwcclusion," which may occur when active hemoperfusion devices are utilized during percutaneous transluminal coronary angioplasty (PTCA). In such cases, contrast injected via the guiding catheter fails to opacify the coronary artery distal to the tip of the dilating catheter, thereby giving the angiographic appearance of coronary occlusion. When active hemoperfusion is terminated, contrast opacities the vessel in a normal fashion. The cause of this observation is likely multifactorial and includes obstruction to flow by the dilating catheter, high distal pressure delivered by the dilating catheter during hemoperfusion competing with the flow of contrast injected via the guiding catheter, and washout of contrast at the tip of the dilating catheter by non-contrast containing blood being pumped through the system. This phenomenon must be recognized if potentially deleterious repeat dilatations are to be avoided.