Abstract

Purpose

To compare the efficacy and safety of two different doses (0.1 and 0.3 mmol/kg of body weight [BW]) of gadodiamide for contrast‐enhanced magnetic resonance angiography (ce‐MRA) of the lower extremities with intraarterial digital subtraction angiography (IA‐DSA).

Materials and Methods

A total of 30 patients with peripheral arterial occlusive disease underwent IA‐DSA and ce‐MRA from the aortic bifurcation down to the ankle. Patients were randomized to receive a total dose of 0.1 or 0.3 mmol/kg of BW gadodiamide (Omniscan, Amersham Buchler), administered intravenously as a series of three automatic bolus injections. Ce‐MRA was performed with a 1.5‐T system using a body phased‐array coil, centered stepwise over the calf, thigh, and pelvic region. A fast T1‐weighted, three‐dimensional gradient‐echo sequence was obtained before and after injection of the allocated dose. IA‐DSA was performed using the Seldinger technique and a femoral approach. The vessels under investigation were divided into 31 segments, and ce‐MRA and IA‐DSA image sets were evaluated in a double‐blind fashion for the presence of stenosis, presence of collateral vessels, vessel delineation, and overall image quality. Both dose groups were compared with regard to contrast index (CI) and signal‐ and contrast‐to‐noise ratios (SNR, CNR). The occurrence of adverse events or side effects was also documented. Sensitivity, specificity, and accuracy were calculated in relation to the results of stenosis grading.

Results

A total of 26 patients were entered in the efficacy evaluation, while all 30 patients were included in the safety assessment. The sensitivity, specificity, and accuracy for the 0.1 and 0.3 mmol/kg dose groups were 78.8%/93.0%/88.9% vs. 60.2.%/91.5%/83.2%, respectively. The detection of collaterals was similar to IA‐DSA for the 0.3 mmol/kg dose group (30.2% vs. 27.4%), but was lower in the 0.1 mmol/kg dose group (27.3% vs. 12.3%). The high‐dose gadodiamide injection proved to be superior to the 0.1 mmol/kg dose group with regard to vessel delineation and overall image quality (P = 0.007 and P = 0.002, respectively). The difference between the two dose groups regarding CI, SNR, and CNR was significant (P = 0.0001), in favor of the 0.3 mmol/kg dose group. No adverse events were observed in any of the patients.

Conclusion

Ce‐MRA with gadodiamide is safe and efficacious. Comparison of two different doses with IA‐DSA as the standard of reference showed that the 0.3 mmol/kg dose is superior to the standard 0.1 mmol/kg dose with respect to contrast enhancement, vessel delineation, image quality, and detection of collaterals. However, the 0.1 mmol/kg dose was superior to the high dose in the grading of stenosis. J. Magn. Reson. Imaging 2005;21:449–454. © 2005 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Dose comparison of single- vs. double-do
✍ C. Jourdan; J.T. Heverhagen; M.V. Knopp 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 344 KB 👁 1 views

## Abstract ## Purpose To compare the intraindividual differences of single‐dose (D~S~) and double‐dose (D~D~) gadolinium diethylenetriamine pentaacetic acid (Gd‐DTPA)‐enhanced magnetic resonance angiography (MRA) in the carotid arterial territory, an open‐label single‐center trial with blinded ev

Low-dose 3D time-resolved magnetic reson
✍ Youn-Joo Lee; Gerhard Laub; So-Lyung Jung; Won-Jong Yoo; Young-Joo Kim; Kook-Jin 📂 Article 📅 2010 🏛 John Wiley and Sons 🌐 English ⚖ 300 KB 👁 1 views

## Abstract ## Purpose To evaluate the feasibility of low‐dose, 3D time‐resolved contrast‐enhanced magnetic resonance angiography (TR‐CEMRA) in the assessment of the supraaortic vessel, and to compare the results with high‐resolution contrast‐enhanced MRA (HR‐CEMRA). ## Materials and Methods Thi

Prospective comparison of image quality
✍ Marina Achenbach; Jens H. Figiel; Mykhaylo Burbelko; Johannes T. Heverhagen 📂 Article 📅 2010 🏛 John Wiley and Sons 🌐 English ⚖ 151 KB

## Abstract ## Purpose To compare image quality and diagnostic accuracy of 0.5 molar gadobenate dimeglumine and 1.0 molar gadobutrol in contrast‐enhanced (CE) magnetic resonance angiography (MRA) of the lower extremities interindividually. ## Materials and Methods The study was approved by our I