## Abstract The purpose of the work was to evaluate the effectiveness of extracellular contrast media in improving MR coronary angiography using breath‐hold segmented echo‐planar imaging (SEPI). Two protocols were designed to optimize the inversion recovery‐prepared contrast‐enhanced SEPI method. I
Contrast-enhanced coronary artery imaging using 3D trueFISP
✍ Scribed by Vibhas S. Deshpande; Debiao Li
- Publisher
- John Wiley and Sons
- Year
- 2003
- Tongue
- English
- Weight
- 319 KB
- Volume
- 50
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
An ECG‐triggered, segmented, magnetization‐prepared, 3D, trueFISP sequence was recently developed for coronary artery imaging. Fat saturation was achieved by a chemically selective fat saturation pulse, which is susceptible to field inhomogeneities. In addition, the blood–myocardial contrast was compromised because data were acquired during signal transience to steady state. The goals of this work were to investigate the potential benefits of T~1~‐shortening agents in improving blood–myocardial contrast, and to develop a technique to make fat suppression robust to resonance offsets for coronary artery imaging using trueFISP. A magnetization‐preparation scheme using saturation and inversion pulses was developed for simultaneous suppression of tissues over a wide range of T~1~'s, including myocardium and fat. An additional advantage of this method is that it is insensitive to heart rate variations. Computer simulations were used to design the magnetization preparation, and volunteer studies were performed to compare precontrast imaging to contrast‐enhanced (CE) imaging. Results showed consistent fat suppression and a 78% increase in the blood–myocardial contrast‐to‐noise ratio (CNR) for postcontrast imaging over precontrast imaging. In conclusion, contrast agents are useful for trueFISP coronary artery imaging. Magn Reson Med 50:570–577, 2003. © 2003 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract Aiming for robust high‐resolution free respiration coronary artery imaging, localized tracking volume selective 3D‐EPI at spatial resolution 1.25 × 1.25 × 3 mm and temporal resolution 65 ms was evaluated in 14 normal subjects. Subject‐specific motion tracking factors were measured betwe
## Abstract Contrast‐enhanced coronary angiography has become an important technique for magnetic resonance (MR) coronary artery imaging. However, the relationship between the quality of the coronary artery images and blood T1 has not yet been fully explored. In this paper, we assessed this relatio
## Abstract ## Purpose To monitor contrast kinetics by acquiring multiple 2D images during 3D contrast‐enhanced magnetic resonance angiography (CE MRA). ## Materials and Methods A 2D real‐time autotriggering tool was integrated into a 3D sequence, enabling it to run multiple times during 3D acqu