Abstract
An integration of SENSitivity Encoding (SENSE) with continuously moving table (CMT) MRI for extended field‐of‐view (FOV) acquisitions is described. In this work, the approach in which receiver coils are attached to the object and move in synchrony with the scanner table is considered. Technical issues dealing with the implementation of SENSE‐CMT are addressed, including coil calibration, correction for non‐uniform magnetic gradients, and specific reconstruction steps. An explanation of combining SENSE with gradient non‐linearity correction is given, as the latter becomes necessary in CMT acquisitions where a large sampling FOV is used. It is hypothesized that SENSE can provide at least a 2‐fold improvement in lateral spatial resolution compared to non‐accelerated CMT acquisitions. The hypothesis is tested in phantoms, where the effectiveness of both SENSE and gradient non‐linearity correction to improve spatial resolution is shown. The SENSE‐CMT technique is further demonstrated in vivo with contrast‐enhanced MR angiography of the peripheral vasculature. Magn Reson Med, 2005. © 2005 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract ## Purpose To investigate if the use of parallel imaging is feasible and beneficial for peripheral contrast‐enhanced magnetic resonance angiography (CE‐MRA). ## Materials and Methods A total of 19 consecutive patients underwent peripheral CE‐MRA using SENSE with two‐fold reduction in
## Abstract The elliptical centric (EC) view order samples a 3DFT acquisition from the center of __k__‐space outward, and when applied to contrast‐enhanced MR angiography (CE‐MRA) provides intrinsic venous suppression. This is because the veins enhance several seconds after the scan is initiated, a
## Abstract ## Purpose To prospectively study the diagnostic performance of hybrid single‐dose contrast‐enhanced MRA of peripheral arterial disease (PAD), with digital subtraction angiography (DSA) as the reference standard. ## Materials and Methods Hybrid MRA, combining time resolved imaging of
## Abstract ## Purpose To report preliminary experience with contrast‐enhanced magnetic resonance angiography (CE‐MRA) of the peripheral arteries on a 3.0 T whole‐body scanner equipped with a prototype body coil. ## Materials and Methods Four healthy volunteers were imaged on the 3.0 T system an