Consistent inelastic design spectra: Hysteretic and input energy
✍ Scribed by Peter Fajfar; Tomaž Vidic
- Publisher
- John Wiley and Sons
- Year
- 1994
- Tongue
- English
- Weight
- 871 KB
- Volume
- 23
- Category
- Article
- ISSN
- 0098-8847
No coin nor oath required. For personal study only.
✦ Synopsis
This is the second of two companion papers on inelastic design spectra (for strength, displacement, hysteretic and input energy) for systems with a prescribed ductility factor. All the spectra are consistent (interrelated and based on the same assumptions). This paper deals with two quantities related to cumulative damage: hysteretic and input energy. The input data for the procedure are the characteristics of the expected ground motion in terms of a smooth elastic pseudoacceleration spectrum and the time integral of the square of the ground acceleration 5 a' dt. Simple, approximate expressions for two dimensionless parameters (the parameter y and the hysteretic to input energy ratio EH/EI) have been proposed. The parameter 7, which controls the reduction of the deformation capacity of structures due to low-cycle fatigue, depends on the natural period of the system, the prescribed ductility factor, the hysteretic behaviour and the ground motion characteristics. The ratio EH/E, is influenced by damping, the ductility factor and the hysteretic behaviour. Very good approximations to the inelastic spectra for hysteretic and input energy can be derived from the elastic spectrum using the spectra for the reduction factor R , proposed in the companion paper, and the proposed values for y and E,/E,.
📜 SIMILAR VOLUMES
## Abstract A procedure for the determination of inelastic design spectra (for strength, displacement, hysteretic and input energy) for systems with a prescribed ductility factor has been developed. All the spectra are consistent (interrelated and based on the same assumptions). This is the first o
This paper presents qualitative investigations on the energy behaviour of structures into which hysteretic dampers are incorporated. Emphasis was given to the ratio of the structural stiffness after the yielding of hysteretic dampers to the initial elastic stiffness, with a premise that this ratio,
## Abstract Robust performance of hysteretic dampers, used in controlling mid‐rise buildings, against change of earthquake characteristics is investigated in this paper. A shear type ten‐storey building incorporating hysteretic dampers is studied as a model under the assumption of elastic perfectly