✦ Synopsis


Abstract

Whenever a linear gradient is activated, concomitant magnetic fields with non‐linear spatial dependence result. This is a consequence of Maxwell's equations, i.e., within the imaging volume the magnetic field must have zero divergence, and has negligible curl. The concomitant, or Maxwell field has been described in the MRI literature for over 10 years. In this paper, we theoretically and experimentally show the existence of two additional lowest‐order terms in the concomitant field, which we call cross‐terms. The concomitant gradient cross‐terms only arise when the longitudinal gradient G~z~ is simultaneously active with a transverse gradient (G~x~ or G~y~). The effect of all of the concomitant gradient terms on phase contrast imaging is examined in detail. Several methods for reducing or eliminating phase errors arising from the concomitant magnetic field are described. The feasibility of a joint pulse sequence‐reconstruction method, which requires no increase in minimum TE, is demonstrated. Since the lowest‐order terms of the concomitant field are proportional to G^2^/B~0~, the importance of concomitant gradient terms is expected to increase given the current interest in systems with stronger gradients and/or weaker main magnetic fields.


📜 SIMILAR VOLUMES


Generalized reconstruction of phase cont
✍ M. Markl; R. Bammer; M.T. Alley; C.J. Elkins; M.T. Draney; A. Barnett; M.E. Mose 📂 Article 📅 2003 🏛 John Wiley and Sons 🌐 English ⚖ 822 KB

## Abstract To characterize gradient field nonuniformity and its effect on velocity encoding in phase contrast (PC) MRI, a generalized model that describes this phenomenon and enables the accurate reconstruction of velocities is presented. In addition to considerable geometric distortions, inhomoge

Analysis and correction of gradient nonl
✍ Johannes M. Peeters; Clemens Bos; Chris J. G. Bakker 📂 Article 📅 2004 🏛 John Wiley and Sons 🌐 English ⚖ 529 KB

## Abstract Phase contrast flow measurements will be increasingly biased at eccentric positions, where nonlinearity of gradients and inhomogeneity of the main field become important. In theory, they scale the result of phase contrast flow values in two ways: incorrect velocity encoding of moving sp