The EBI (BARD-XT, C.R. Bard, Murray Hill, NJ) stent is a new radiopaque balloon expandable coronary stent with high resistance to external radial forces. It does not shorten significantly with expansion and allows stent implantation in bifurcation lesions. A total of 28 EBI stents were implanted in
Concept of the homemade coronary stent: Experimental results and initial clinical experience
β Scribed by De Scheerder, Ivan K. ;Wang, Kai ;Kerdsinchai, Pitsanu ;Verbeken, Eric ;Desmet, Walter ;Dens, Jo ;Wilczek, Krzysztof ;Humbeeck, Jan Van ;Piessens, Jan H.
- Publisher
- John Wiley and Sons
- Year
- 1996
- Tongue
- English
- Weight
- 612 KB
- Volume
- 39
- Category
- Article
- ISSN
- 0098-6569
No coin nor oath required. For personal study only.
β¦ Synopsis
To defray the escalating cost of coronary stenting, we handmade a balloon expandable coil stent with stainless steel wire. Preliminary comparison with the Palmaz-Schatz stent showed that, when implanted in porcine iliac arteries, there was no difference in immediate angiographic results or in the degree of foreign body reaction at 6 wk. Subsequently, a total of 73 stents were implanted in 52 patients, either as a bailout device (54%) or for suboptimal angiographic results (46%).
All but two implantations were successful. The postprocedural regimen consisted of heparin 1,000 IUlhr, aspirin 250 mg daily, and ticlopidine 500 mg daily. In-hospital complications were limited to two groin hematomas, one necessitating blood transfusion. Importantly, stent thrombosis was not observed. While 6-rno follow-up is pending, we already conclude that a balloon expandable coil stent can be handmade easily at low cost and implanted safely in patients. o 1996 Wiiey-Liss, inc.
π SIMILAR VOLUMES
To evaluate the results of long Micro Stent II (MS-XL) implantations, 119 MS-XLs were implanted in 102 patients (age, 62.83 years). Nineteen stents (16%) were implanted in saphenous vein grafts; 100 stents (84%) were implanted in native coronary arteries. Twenty-five patients (25%) were treated beca
The Palmaz-Schatz (PS) stent has effectively reduced restenosis; however its rigidity makes it sometimes difficult or impossible to deliver. The initial and follow-up outcomes with the ACS Multi-Link stent (deployed from April to November 1995) were evaluated in 70 patients (79 lesions): unplanned i
Coating stents with autologous venous grafts has been suggested to prevent problems associated with conventional stenting, but the need for surgical vessel harvest hampered broad application. A novel synthetic coronary stent graft (CSG) overcomes this limitation by a synthetic membrane, fixed betwee