For a number of reasons, it is desirable to fabricate coils which, for a known current, shall produce predetermined values of the magnetic field intensity at a number of points within a nuclear magnetic resonance imager. The calculation of the magnetic field intensity at a set of points involves th

Computer-assisted imaging of the fetus w
✍ Patrick M. Colletti πŸ“‚ Article πŸ“… 1996 πŸ› Elsevier Science 🌐 English βš– 583 KB

The purpose of this paper is to review the use of magMic reuomu~ imaging(MRI)oftbefetasaadto propose fatnre tedmiqws and applications. lnstitn~nal re!view board apprWed MB image8 of the fetns were acquiradia66patieatswithsoaog+hUy saspe&dfetalabnorn&tks.Axial,eoraacll,aad short TE images were obtaln

Magnetic resonance imaging of the uterin
✍ C. J. Baudouin; W. P. Soutter; D. J. Gilderdale; G. A. Coutts πŸ“‚ Article πŸ“… 1992 πŸ› John Wiley and Sons 🌐 English βš– 402 KB πŸ‘ 1 views

## Abstract Cylindrical receiver coils designed for intravaginal use were utilized to image the uterine cervix. Good quality images of the cervix, vaginal wall, and parametrium were obtained and patient tolerance of the procedure was good. Β© 1992 Academic Press, Inc.

Transceive surface coil array for magnet
✍ Robert G. Pinkerton; Enzo A. Barberi; Ravi S. Menon πŸ“‚ Article πŸ“… 2005 πŸ› John Wiley and Sons 🌐 English βš– 339 KB πŸ‘ 1 views

## Abstract As the static magnetic field strength used in human magnetic resonance imaging increases, the wavelength of the corresponding radiofrequency field becomes comparable to the dimensions of the coil and volume of interest. The dielectric resonance effects that arise in this full wavelength

A solid reusable endorectal receiver coi
✍ Nandita M. Desouza; David J. Gilderdale; Rakesh Puni; Glyn A. Coutts; Ian R. You πŸ“‚ Article πŸ“… 1996 πŸ› John Wiley and Sons 🌐 English βš– 469 KB πŸ‘ 1 views

## Abstract We have designed a solid endorectal receiver coil for MRI of the prostate. The coil provided an improved signal‐to‐noise ratio up to 5 cm from its surface when compared with a standard pelvic phased array. This preliminary report describes 16 patients who were imaged using this coil, se