## 93-2730 Development of Hydrogen Water Chemistry in Fugen Nuclear Power Station. Hydrogen water chemistry (HWC) was applied to the Fugen Nuclear Power Station. This is the first application of HWC in Japan as a countermeasure against stress corrosion cracking (SCC) of Type 304 stainless steel. A
Comprehensive papers covering several materials
- Book ID
- 102936721
- Publisher
- John Wiley and Sons
- Year
- 1986
- Tongue
- German
- Weight
- 542 KB
- Volume
- 37
- Category
- Article
- ISSN
- 0947-5117
No coin nor oath required. For personal study only.
โฆ Synopsis
Abstr. 347-358 R27
86-0347 Secondary Effects in Ion Bombardment Induced Surface Erosion. Some secondary effects identified as important contributors to surface morphological changes, i e., ion reflection, lorward peak emission and redeposition of sputtered atoms and particles, surface energylsurface tension-induced changes, ion beam-divergence-induced modifications, latent plane related effects, radiation damage. and collision cascade density effects, are discussed. The role of surface energy in determining the shape of asperities such as cones and pyramids is examined, and mechanisms for changes of shape driven by the necessity to minimize surface energy and surface stress are identified. The theory of bending by surface-induced plastic deformation is verified experimentally. 94 ref.
-H.S.
๐ SIMILAR VOLUMES
Werkstoffe und Korrosion 40, (1989) called "stochastic process". The analysis of potential and current noise can give important information on the characteristics of metallic surface, especially about the layers on the surface which can hinder the corrosion reactions or can even totally block it. 5
life is reached, exhaustion calculations are performed using a proper creep equation. From that point. the components are then followed periodically. by non destructive (second phase) and destructive (third phase) well-tried testing methods. The results are interpreted in a correlated manner The com
Werkstoffe und Korrosion 41, (1990) tative characterization of intergranular stress corrosion cracking (IGSCC) from results of constant extension rate tests (CERTs) is presented. The basic experimental datum used is the morphological information present in a specimen at the end of a CERT; this infor
tions: as obtained. solution anneal, sensitized in protective atmosphere and sensitized in air The tests were as follows: (a) in 1:l boiling hydrochloric acid and two periods of immersion with weight loss determination; (b) in ferric sulfate/ sulfuric acid, with the same determinations; (c) in 65% b