## Abstract ## Purpose: To provide a quantitative assessment of motion and distortion correction of diffusion‐weighted images (DWIs) of the breast and to evaluate the effects of registration on the mean apparent diffusion coefficient (mADC). ## Materials and Methods: Eight datasets from four pat
Comprehensive approach for correction of motion and distortion in diffusion-weighted MRI
✍ Scribed by G.K. Rohde; A.S. Barnett; P.J. Basser; S. Marenco; C. Pierpaoli
- Publisher
- John Wiley and Sons
- Year
- 2003
- Tongue
- English
- Weight
- 356 KB
- Volume
- 51
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Patient motion and image distortion induced by eddy currents cause artifacts in maps of diffusion parameters computed from diffusion‐weighted (DW) images. A novel and comprehensive approach to correct for spatial misalignment of DW imaging (DWI) volumes acquired with different strengths and orientations of the diffusion sensitizing gradients is presented. This approach uses a mutual information‐based registration technique and a spatial transformation model containing parameters that correct for eddy current‐induced image distortion and rigid body motion in three dimensions. All parameters are optimized simultaneously for an accurate and fast solution to the registration problem. The images can also be registered to a normalized template with a single interpolation step without additional computational cost. Following registration, the signal amplitude of each DWI volume is corrected to account for size variations of the object produced by the distortion correction, and the __b‐__matrices are properly recalculated to account for any rotation applied during registration. Both qualitative and quantitative results show that this approach produces a significant improvement of diffusion tensor imaging (DTI) data acquired in the human brain. Magn Reson Med 51:103–114, 2004. Published 2003 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract Diffusion‐weighted images acquired with the echo‐planar imaging technique are highly sensitive to eddy current induced geometric distortions that vary with the magnitude and direction of the diffusion sensitizing gradients. Such distortions cause misalignment of images acquired with dif
## Abstract Diffusion‐weighted MRI is a clinically useful technique, but its utility is compromised by high sensitivity to patient motion. Use of radial‐scan data acquisition and projection reconstruction, rather than the conventional Fourier imaging method, can substantially reduce the sensitivity
## Abstract ## Purpose: To retrospectively determine the additional value of diffusion‐weighted magnetic resonance imaging (MRI) to T2‐weighted imaging in the evaluation of anal fistulae in comparison with gadolinium (Gd)‐enhanced imaging. ## Materials and Methods: Thirteen patients (mean age, 3
## Abstract ## Purpose: To compare diffusion‐weighted imaging (DWI) and magnetic resonance (MR) volumetry for predicting treatment outcomes of locally advanced rectal cancers with preoperative chemoradiotherapy (CRT). ## Materials and Methods: This prospective study was approved by our Instituti