๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Comparison of two doses of endotracheal epinephrine in a cardiac arrest model

โœ Scribed by Steven G Crespo; John M Schoffstall; Leanne R Fuhs; William H Spivey


Publisher
Elsevier Science
Year
1991
Tongue
English
Weight
549 KB
Volume
20
Category
Article
ISSN
1097-6760

No coin nor oath required. For personal study only.

โœฆ Synopsis


Study objective:

The objective of this study was to measure plasma catecholamine levels and the cardiovascular response before and after endotracheal administration of epinephrine in a swine cardiac arrest model.

Design: Prospective, controlled laboratory investigation.

Type of participants: Twenty-one swine weighing 10 to 12 kg, anesthetized with ketamine and ~-chloralose and ventilated with room air.

Interventions: Ventricular fibrillation was induced w~th 90 V of 60 Hz current delivered to the right ventricle by transvenous pacemaker. Blood samples for epinephrine were drawn before arrest and every two minutes thereafter. At five minutes, external mechanical cardiac compressions were initiated. Nine animals received no .further therapy and served as controls. Two groups of six animals received either 0.01 mg/kg or 0.1 mg/ kg of epinephrine through the endotracheal tube at ten and 20 minutes. Blood samples were assayed for epinephrine.

Measurements: Arterial blood pressure, lead II ECG, and plasma epinephrine.

Main results: Swine receiving epinephrine 0.01 mg/kg had an increase in epinephrine levels after drug administration, but these were not significantly different from control levels. The O.l-mg/kg dose group had a significant increase in plasma epinephrine levels compared with controls and the O.Ol-mg/kg dose group after receiving epinephrine at ten and 20 minutes. These increases were from 14 +-3 to 215 +_ 40 ng/mL (ยฑ SEM) at i2 minutes after arrest and from 151 +_ 56 to 402 +_ 80 ng/mL at 22 minutes after arrest.

Conclusion: These data suggest that standard dosing of epinephrine through the endotracheaI tube during arrest does not produce significant increases in plasma catecholamines or blood pressure. Epinephrine 0.1 mg/ kg produces a significant increase in plasma epinephrine levels, but it is not sufficient to produce a significant change in blood pressure.


๐Ÿ“œ SIMILAR VOLUMES


A standard comparison of esophageal obtu
โœ Yvonne Hammargren; Joseph E Clinton; Ernest Ruiz ๐Ÿ“‚ Article ๐Ÿ“… 1985 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 556 KB

A comparison of esophageal obturator airway ยฎ (EOA ยฎ) and endotracheal tube (ET) ventilation was performed while standardizing the method of oxygen delivery and assuring true sampling of arterial blood. Forty-eight victims of prehospital cardiac arrest had an arterial blood gas drawn in the emergenc

High-dose epinephrine improves the retur
โœ Christopher Barton; Michael Callaham ๐Ÿ“‚ Article ๐Ÿ“… 1991 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 444 KB

## To evaluate the return of spontaneous circulation (RSC) rates in human victims of cardiac arrest treated with standard doses of epinephrine (SDE) or high-dose epinephrine (HDE). Design: Prospective case series. Setting: A university hospital emergency department during 1987 through I989. Part