๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Comparison of the trabecular and cortical tissue moduli from human iliac crests

โœ Scribed by Dr. J. L. Kuhn; S. A. Goldstein; R. Choi; M. London; L. A. Feldkamp; L. S. Matthews


Publisher
Elsevier Science
Year
1989
Tongue
English
Weight
843 KB
Volume
7
Category
Article
ISSN
0736-0266

No coin nor oath required. For personal study only.

โœฆ Synopsis


The purpose of this study was to design a method to produce and test mechanically microspecimens of trabecular and cortical tissue from human iliac crests, and compare their measured moduli. Rectangular beam specimens were prepared on a low-speed diamond blade saw and a miniature milling machine. The final specimen dimensions ranged from -5G200 pm for base and height. The modulus of each specimen was measured using three-point bending tests across a span length of 1.04 mm and performed at a constant rate of displacement. A subset of specimens was recovered for a radiographic estimation of degree of mineralization. The results showed the mean trabecular tissue modulus of all iliac crest specimens to be 3.81 GPa, whereas cortical tissue specimens averaged 4.89 GPa. This was a significant difference according to a two-way analysis of variance that controlled for differences between donors. No strong correlations were found between modulus and mineral density. Future investigations that consider other microstructural characteristics and their contributions to modulus, and specimen size effects, are indicated.


๐Ÿ“œ SIMILAR VOLUMES


Comparison of the electrical and dielect
โœ Subrata Saha; Paul Allen Williams ๐Ÿ“‚ Article ๐Ÿ“… 1995 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 721 KB

## Abstract We compared the electrical and dielectric properties of wet human cortical and cancellous bone tissue from the distal tibia. The relationships between the electrical and dielectric behavior of cortical and cancellous bone and variables of measurement such as frequency and direction (ori