Comparison of the effectiveness of saturation pulses in the heart at 3T

✍ Scribed by Daniel Kim; Oded Gonen; Niels Oesingmann; Leon Axel


Publisher
John Wiley and Sons
Year
2007
Tongue
English
Weight
475 KB
Volume
59
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Cardiac MRI at 3T provides a means to increase the contrast‐to‐noise ratio (CNR) for first‐pass perfusion MRI. However, both the static magnetic field (B~0~) and radio frequency (RF) field (B~1~) variations within the heart are comparatively higher at 3T than at 1.5T. The increased field variations can degrade the performance of a single rectangular saturation pulse that is conventionally used for magnetization preparation. The accuracy of T~1~‐weighted signal measurement depends on the uniformity of the magnetization saturation. The purpose of this study was to assess the relative effectiveness of the rectangular, pulse train, and adiabatic composite (BIR‐4) saturation pulses in the human heart at 3T. In volunteers, after nominal saturation, the mean residual magnetization within the left ventricle (LV) was different between all three pulses (0.13 ± 0.06 vs. 0.03 ± 0.02 vs. 0.03 ± 0.01, respectively; P < 0.001). Within paired groups, the mean residual magnetization was significantly higher for the rectangular pulse than for either the pulse train and BIR‐4 pulses (P < 0.001), but not different between the pulse train and BIR‐4 pulses. The performances of all three saturation pulses were comparatively poorer in the right ventricle (RV) than in the LV, respectively. Magn Reson Med, 2007. © 2007 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Renal perfusion: Comparison of saturatio
✍ Henrik J. Michaely; Kambiz Nael; Stefan O. Schoenberg; J. Paul Finn; Niels Oesin 📂 Article 📅 2006 🏛 John Wiley and Sons 🌐 English ⚖ 563 KB

## Abstract ## Purpose To investigate the dependence of semiquantitative renal perfusion parameters on the acquisition technique and field strength used. ## Materials and Methods After intravenous injection of 7‐mL Gd‐chelates, high‐temporal‐resolution turbo fast low‐angle shot (TurboFLASH) rena

Measurement and characterization of RF n
✍ Kyunghyun Sung; Krishna S. Nayak 📂 Article 📅 2008 🏛 John Wiley and Sons 🌐 English ⚖ 535 KB

## Abstract ## Purpose To measure and characterize variations in the transmitted radio frequency (RF) (B1+) field in cardiac magnetic resonance imaging (MRI) at 3 Tesla. Knowledge of the B1+ field is necessary for the calibration of pulse sequences, image‐based quantitation, and signal‐to‐noise ra