𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Comparison of the automated fluorescence microscopic viability test with the conventional and flow cytometry methods

✍ Scribed by Jang Su Kim; Myung Hyun Nam; Seong Soo A. An; Chae Seung Lim; Dae Sung Hur; Chanil Chung; Jun Koon Chang


Publisher
John Wiley and Sons
Year
2011
Tongue
English
Weight
105 KB
Volume
25
Category
Article
ISSN
0887-8013

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

The cell viability test is an essential tool in any laboratory, performing cell‐based studies and clinical laboratory tests. The trypan blue exclusion method is the most popular assay for its simple concept among various diagnostic tools. However, several disadvantages include time‐consuming and labor‐intensive steps with low precision. In this study, we evaluated a new technique for the automatic cell viability measurement with microscopic cell counter and microchip. Upon blood draw from 11 healthy volunteers, Mononuclear cells were separated immediately from the heparinized whole blood, and the viable cells were diluted from 100 to 1%. The cell viability tests were performed simultaneously with following three methods: the conventional manual trypan blue exclusion method; the flow cytometry measurement with propidium iodide stain; and the newly developed microscopic cell counter with microchip. Linearities, precisions, and correlations from three methods were analyzed and compared. The correlations data from the microscopic cell counter were in good agreement with both the conventional trypan blue method (r=0.99, P<0.05) and the flow cytometry (r=0.99, P<0.05), respectively. The precision (2.0–6.2%) and linearity from the microscopic cell counter method with microchip were superior in comparison with the conventional method. The microscopic cell counter with microchip performed well with high precision, linearity, and efficient running time than both the manual trypan blue and the flow cytometry methods. J. Clin. Lab. Anal. 25:90–94, 2011. © 2011 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Clinical laboratory automated urinalysis
✍ S. Mayo; D. Acevedo; C. Quiñones-Torrelo; I. Canós; M. Sancho 📂 Article 📅 2008 🏛 John Wiley and Sons 🌐 English ⚖ 136 KB

## Abstract Urinalysis is one of the habitual clinical laboratory procedures, which implies that one of the largest sample volumes currently requires significant labor to examine microscopic sediments. Different analyzers currently used to perform this task have been compared with the manual micros

Evaluation of four monoclonal antibodies
✍ J. Neumüller; D. W. M. Schwartz; E. Dauber; W. R. Mayr 📂 Article 📅 1996 🏛 John Wiley and Sons 🌐 English ⚖ 594 KB

Typing for HLA-B27 by serological methods is routinely performed using the microlymphocytotoxic test (MLCT). Since monoclonal antibodies (MAB) against HLA-B27 are available, flow cytometry (FC), which requires less time than the MLCT has been developed as an alternative technique. The aim of the pre