COMPARISON OF SUBJECTIVE RESPONSES TO VIBRATION AND SHOCK WITH STANDARD ANALYSIS METHODS AND ABSORBED POWER
✍ Scribed by N.J. MANSFIELD; P. HOLMLUND; R. LUNDSTRÖM
- Book ID
- 102610083
- Publisher
- Elsevier Science
- Year
- 2000
- Tongue
- English
- Weight
- 161 KB
- Volume
- 230
- Category
- Article
- ISSN
- 0022-460X
No coin nor oath required. For personal study only.
✦ Synopsis
Evaluation of human exposure whole-body vibration (WBV) and shock can be carried out in a variety of ways. The most commonly used standards for predicting discomfort from WBV are BS6841 (1987) and ISO2631-1 (1997) which o!er di!erent frequency weightings (= @ and = I ) and three methods of assessment: vibration dose value (VDV), estimated VDV (eVDV) and maximum transient vibration value (MTVV). Previous studies have also used DRI and absorbed power for assessments of shock and WBV. This paper reports a laboratory study in which 24 human subjects were exposed to 15 vertical vibration stimuli comprising of random vibration, repeated shocks and combinations of random vibration and shocks at 0)5, 1)0 and 1)5 m/s r.m.s. Subjects rated the discomfort from the vibration on a numerical scale after each exposure. Acquired acceleration signals were analyzed using VDV, r.m.s. and MTVV for unweighted, = @ , = I and DRI weighted signals. Acceleration and force were combined to give a measure of absorbed power. Subjective responses were correlated to vibration magnitude for the 13 analysis types. VDV was the best standard method of assessment; MTVV was the worst. = @ and = I frequency weightings showed slightly greater correlations between vibration magnitude and discomfort than DRI weighted or unweighted signals. For VDV, there were no signi"cant di!erences between the correlations obtained using any frequency weighting. For assessment of all stimuli types together, absorbed power gave higher correlations with subjective discomfort than acceleration-based methods. It is concluded that the methods described in ISO2631-1 should be clari"ed and simpli"ed. Due to the di$culty in measuring absorbed power in the "eld, methods proposed in BS6841 are recommended as the most appropriate for assessment of discomfort from continuous vibration or repeated shocks.
📜 SIMILAR VOLUMES
## Abstract Microcolumn chromatography (1.0 mm to 0.3 mm column i.d.) of underivatized amino acids coupled to evaporative light‐scattering (ELS) detection demonstrated good baseline stability using perfluorinated carboxylic acid ion‐pairing agents of varying alkyl chain lengths (C~2~–C~8~) and conc