𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Comparison of methodological uncertainties within permeability measurements

✍ Scribed by Nick A. Chappell; James W. Lancaster


Publisher
John Wiley and Sons
Year
2007
Tongue
English
Weight
303 KB
Volume
21
Category
Article
ISSN
0885-6087

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Permeability measurements are critical to the calculation of water‐flow within hillslopes. Despite this, errors in permeability measurements are often ignored, and can be very large particularly in disturbance‐sensitive gley soils. This work compares the uncertainties associated with six field methods of permeametry applied to a gleyed soil in upland Britain. Slug tests, constant‐head borehole permeametry, and falling‐head borehole permeametry were undertaken on established piezometers. Additionally, ring permeametry and two types of trench tests were evaluated.

Method‐related uncertainty due to proximity of impeding layers of high sorptivity soils produces under‐ and over‐estimates of permeability by a factor of up to 0·2 and 5, respectively. This uncertainty band is smaller than the observed effects of anisotropy and temporal variability. Had smearing and soil‐ring leakage errors not been minimized, the methodological uncertainties would have been so large that they would have distorted the true spatial field of permeability and its estimated impact on the balance of vertical and lateral flow. Copyright © 2007 John Wiley & Sons, Ltd.


📜 SIMILAR VOLUMES


Methodological evaluation and comparison
✍ Rui Liu; Gang Li; Xiao-Fan Cui; Dong-Ling Zhang; Qing-Hong Yang; Xiao-Yan Mu; We 📂 Article 📅 2011 🏛 John Wiley and Sons 🌐 English ⚖ 189 KB

## Abstract __Background__: Microalbuminuria is an indicator of kidney damage and a risk factor for the progression kidney disease, cardiovascular disease, and so on. Therefore, accurate and precise measurement of urinary albumin is critical. However, there are no reference measurement procedures a

Comparison of two methods to measure per
✍ De La Macorra, Jose C. ;Escribano, Nuria I. 📂 Article 📅 2002 🏛 John Wiley and Sons 🌐 English ⚖ 126 KB

Dentin permeability was measured alternatively with two methods: a 10-microl capillary method with visual evaluation (PC) and a motorized automatic measuring device (Flodec, FD), both interposed in a simulated perfusion system. Eight human third molar coronal fragments were connected to systems, and

On the Methanol Permeability through Pri
✍ S. Mollá; V. Compañ; S. Luis Lafuente; J. Prats 📂 Article 📅 2011 🏛 John Wiley and Sons 🌐 English ⚖ 274 KB

## Abstract Methanol crossover through polymer electrolyte membranes is a critical issue and causes an important reduction of performance in direct methanol fuel cells (DMFCs). Measuring the evolution of CO~2~ gas in the cathode is a common method to determine the methanol crossover under real oper