## Abstract ## Purpose To compare radial and spiral k‐space sampling in navigator‐gated ECG‐triggered three‐dimensional (3D) coronary vessel wall imaging. ## Materials and Methods The right coronary artery (RCA) vessel walls of eight healthy subjects were imaged using a modified double‐inversion
Comparison of k-space sampling schemes for multidimensional MR spectroscopic imaging
✍ Scribed by James W. Hugg; Andrew A. Maudsley; Michael W. Weiner; Gerald B. Matson
- Publisher
- John Wiley and Sons
- Year
- 2005
- Tongue
- English
- Weight
- 495 KB
- Volume
- 36
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
For clinical ^31^P MR spectroscopic imaging (MRSI) studies, where signal averaging is necessary, some improvement of sensitivity and spatial response function may be achieved by acquiring data over a spherical k‐space volume and varying the number of averages acquired in proportion to the desired spatial filter. Eight different k‐space sampling schemes are compared through simulations that provide graphs of the spatial response functions (SRF), and tabulations of voxel volumes, relative signal‐to‐noise ratios (SNR), and relative data collection efficiencies (SNR per unit volume over the same time). All schemes were based on practical experiments, each of which could be implemented in the same length of time. The results show that in comparison with cubic k‐space sampling with the same number of signal averages at each point, spherical and acquisition‐weighted k‐space sampling can be used to achieve reduced Gibbs ringing along the principal axes directions, and thus reduced contamination from adjacent tissue in these directions, without degradation of voxel volume or SNR.
📜 SIMILAR VOLUMES
The multidimensional partition model, which combines the k-space description of magnetic resonance imaging pulse sequences with a partition concept, has been developed to model flow-related effects. A partition represents the magnetization created due to excitation by a given radiofrequency pulse. I
## Abstract In vivo proton MR spectroscopic imaging (MRSI) of human brain is complicated by the presence of a strong signal from subcutaneous lipids, which may result in signal contamination in metabolite images obtained following Fourier‐transform reconstruction. In this study, two approaches for
## Abstract ## Purpose To evaluate differences in velocity and flow measurements in the aorta between accelerated phase‐contrast (PC) magnetic resonance imaging (MRI) using SENSE and k‐t BLAST and in peak velocity to Doppler ultrasound. ## Materials and Methods Two‐dimensional PC‐MRI perpendicul