𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Comparison of dynamic gadolinium-enhanced and ferumoxides-enhanced MRI of the liver on high- and low-field scanners

✍ Scribed by Piyaporn Limanond; Steven S. Raman; James Sayre; David S.K. Lu


Publisher
John Wiley and Sons
Year
2004
Tongue
English
Weight
468 KB
Volume
20
Category
Article
ISSN
1053-1807

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Purpose

To compare the performance of dynamic gadolinium‐enhanced and ferumoxides‐enhanced MRI in the detection and characterization of hepatic lesions, on 1.5‐T and 0.2‐T magnets

Materials and Methods

In 41 patients (23 men, 18 women), 52 hepatic MR examinations were performed and retrospectively analyzed; 39 and 13 examinations were performed on 1.5‐T and 0.2‐T magnets, respectively. A total of 33 of 41 patients had known malignancies, and 31 of 33 patients had biopsy of at least one lesion. First, a combination of unenhanced T2‐weighted sequences and gradient‐echo T1‐weighted sequences were performed. Then, dynamic gadolinium‐enhanced (0.1 mmol/kg) T1 GRE sequences were obtained, followed by intravenous drip infusion of ferumoxides (10 μmol/kg). The T2‐weighted sequences were then repeated. The unenhanced and gadolinium‐enhanced images (the Gd set) were reviewed separately from the unenhanced and ferumoxides‐enhanced images (the ferumoxides set) by two abdominal imagers. The reviewers were blinded to clinical history and reviewed the individual studies in each set randomly. Each detected lesion was scored on a five‐point scale for characterization scores: nonsolid (1 or 2), indeterminate (3), or solid (4 or 5). A consensus review was then performed correlating all available pathology, imaging, clinical findings, and follow‐up to act as a gold standard. Receiver‐operating‐characteristic (ROC) curves were generated and both area‐under‐the‐curve (Az values) and sensitivity values were calculated. Significance of Az and sensitivity differences was assessed using standard Z‐test and chi‐square.

Results

Of 270 lesions detected by consensus, 211 were on 1.5‐T and 59 were on 0.2‐T scanners. The accuracy (Az values) of lesion detection overall, of both readers, was greater for the ferumoxides set than for the Gd set (reader 1: 0.95 vs. 0.89 (P < 0.05); reader 2: 0.91 vs. 0.78 (P < 0.05)). Az values for both readers were greater on the ferumoxides set for both the 1.5‐T scans and the 0.2‐T scans. Out of 270 lesions detected, 231 were characterized by consensus review as solid (185) or nonsolid (46). There was a significant improvement in lesion characterization for both readers on the GD set compared with the ferumoxides set on both high and low field scanners (Az reader 1: 0.99 vs. 0.96 (P < 0.05); Az reader 2: 0.99 vs. 0.95 (P < 0.05)), respectively.

Conclusion

At both 1.5‐T and 0.2‐T, ferumoxides‐enhanced sequences were better for lesion detection, while gadolinium‐enhanced sequences were better for lesion characterization, respectively. J. Magn. Reson. Imaging 2004;20:640–647. © 2004 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Dynamic gadolinium-enhanced echo-planar
✍ Peter Reimer; Sanjay Saini; Ken K. Kwong; Mark S. Cohen; Ralph Weissleder; Thoma 📂 Article 📅 1994 🏛 John Wiley and Sons 🌐 English ⚖ 524 KB

## Abstract To develop guidelines for clinical magnetic resonance imaging of the liver, the authors undertook an animal study to investigate the effect of dose and pulse sequence on liver signal intensity in gadopentetate dimeglumine—enhanced echo‐planar imaging. Serial imaging of the liver was per

Sequential use of ferumoxide particles a
✍ Richard C. Semelka; Joseph K. T. Lee; Suvipapun Worawattanakul; Tara C. Noone; R 📂 Article 📅 1998 🏛 John Wiley and Sons 🌐 English ⚖ 594 KB

## Abstract This study describes the sequential use of ferumoxide (superparamagnetic iron oxide) particles and nonspecific extracellular gadolinium chelate (Gd) for evaluation of focal liver lesions on MRI to evaluate order of contrast administration and imaging effect of the first contrast agent o

Preoperative evaluation of pancreatic ca
✍ Hee Sun Park; Jeong Min Lee; Hei Kyung Choi; Sung Hyun Hong; Joon Koo Han; Byung 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 564 KB

## Abstract ## Purpose To determine the accuracy of magnetic resonance imaging (MRI) including dynamic imaging using three‐dimensional gradient‐echo (3D‐GRE) sequences and MR cholangiopancreatograpy (MRCP) compared with that of multidetector row CT (MDCT) with regard to resectability in pancreas c

Focal liver lesions: Comparison of dual-
✍ Richard C. Semelka; Diego R. Martin; Cem Balci; Trang Lance 📂 Article 📅 2001 🏛 John Wiley and Sons 🌐 English ⚖ 150 KB

## Abstract The purpose of this study was to compare dual‐phase spiral computed tomography (CT) and magnetic resonance imaging (MRI) using dynamic gadolinium enhancement for liver lesion detection and characterization. Twenty‐two consecutive patients underwent dual‐phase spiral CT and MRI for the e

Comparison of single- and dual-tracer ph
✍ Robert C. Orth; James Bankson; Roger Price; Edward F. Jackson 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 225 KB

## Abstract Pharmacokinetic parameters corresponding to perfused microvascular volume determined from dynamic contrast‐enhanced (DCE) MRI data were compared to immunohistochemical measures of microvascular density (MVD) and perfused microvascular density. DCE MRI data from human mammary tumors (MDA

B1 transmission-field inhomogeneity and
✍ Che A. Azlan; Pierluigi Di Giovanni; Trevor S. Ahearn; Scott I.K. Semple; Fiona 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 200 KB 👁 1 views

## Abstract ## Purpose: To quantify B~1~ transmission‐field inhomogeneity in breast imaging of normal volunteers at 3T using 3D T~1~‐weighted spoiled gradient echo and to assess the resulting errors in enhancement ratio (ER) measured in dynamic contrast‐enhanced MRI (DCE‐MRI) studies of the breast