✦ Synopsis


Recent laboratory and epidemiological results have stimulated interest in the hypothesis that human beings may exhibit biological responses to magnetic and/or electric field transients with frequencies in the range between 100 Hz and 100 kHz. Much can be learned about the response of a system to a transient stimulation by understanding its response to sinusoidal disturbances over the entire frequency range of interest. Thus, the main effort of this paper was to compare the strengths of the electric fields induced in homogeneous ellipsoidal models by uniform 100 Hz through 100 kHz electric and magnetic fields. Over this frequency range, external electric fields of about 25-2000 V/m (depending primarily on the orientation of the body relative to the field) are required to induce electric fields inside models of adults and children that are similar in strength to those induced by an external 1 microT magnetic field. Additional analysis indicates that electric fields induced by uniform external electric and magnetic fields and by the nonuniform electric and magnetic fields produced by idealized point sources will not differ by more than a factor of two until the sources are brought close to the body. Published data on electric and magnetic field transients in residential environments indicate that, for most field orientations, the magnetic component will induce stronger electric fields inside adults and children than the electric component. This conclusion is also true for the currents induced in humans by typical levels of 60 Hz electric and magnetic fields in U.S. residences.


πŸ“œ SIMILAR VOLUMES


Inter-laboratory comparison of numerical
✍ M.A. Stuchly; O.P. Gandhi πŸ“‚ Article πŸ“… 2000 πŸ› John Wiley and Sons 🌐 English βš– 97 KB πŸ‘ 2 views

In recent years, with the availability of high resolution models of the human body, numerical computations of induced electric fields and currents have been made in more than one laboratory for various exposure conditions. Despite the verification of computational methods, questions are often asked

Current density in a model of a human bo
✍ BlaΕΎ Valič; Peter GajΕ‘ek; Damijan Miklavčič πŸ“‚ Article πŸ“… 2009 πŸ› John Wiley and Sons 🌐 English βš– 199 KB

## Abstract A numerical model of a human body with an intramedullary nail in the femur was built to evaluate the effects of the implant on the current density distribution in extremely low frequency electric and magnetic fields. The intramedullary nail was chosen because it is one of the longest hi