Comparison of continuous-wave, chop-wave, and super pulse laser wounds
β Scribed by Raymond J. Lanzafame; John O. Naim; David W. Rogers; J. Raymond Hinshaw
- Publisher
- John Wiley and Sons
- Year
- 1988
- Tongue
- English
- Weight
- 628 KB
- Volume
- 8
- Category
- Article
- ISSN
- 0196-8092
No coin nor oath required. For personal study only.
β¦ Synopsis
Some of the latest generation of CO2 lasers incorporate features that alter the wave form. The present study was undertaken to evaluate the relative zone of coagulation in acute laser wounds created in continuous-wave (CW), chop-wave (CPW), and super pulse wave (SPW) modes. The damage from single-point impact sites and incisions was compared in a guinea pig model. Animals were anesthetized with pentobarbital, and wounds were created with a 125-mm handpiece in focus (0.2-mm spot size) on dorsal and flank skin sites with the Sharplan 743 and 1100 CO2 lasers (Sharplan, Ltd., Allendale, NJ). Point impacts of CW and CPW were compared at power levels of 5, 10, 25, 40, 60, and 80 W at time durations of 0.05, 0.1, 0.2, and 0.5 seconds. Incisions of 3.0 cm were created at 25 W in CW, CPW, and SPW modes. Histologic sections stained with hematoxylin and eosin and Van Giesen elastin stains were evaluated by a single observer (R.J.L.). Zones of coagulation for the point-impact study varied from 79 to 257 +/- 66 (SD) micron in width with no significant differences between any of the wounds. Greater thermal damage (coagulation) occurred as the time interval increased. The zones of coagulation in the incision study were 309 +/- 83 (SD) micron for CW, 238 +/- 51 (SD) micron for SPW1 (743), 260 +/- 79 (SD) micron for CPW, and 194 +/- 56 (SD) micron for SPW2 (1100). These results are significant to the P less than 0.01 level.(ABSTRACT TRUNCATED AT 250 WORDS)
π SIMILAR VOLUMES
## Abstract Pulsed and continuousβwave (CW) lasers were compared as excitation sources for surfaceβenhanced resonance Raman scattering (SERRS). CW excitation provided SERRS spectra with a greater signalβtoβnoise ratio and more sensitive detection by a factor of βΌ50 compared with the high peak power
## Background and objectives: The advantages of the continuous wave (c.w.) co(2) laser are offset by the delay in laser wound healing secondary to thermal damage. we have developed novel heat-conducting templates to reduce laser thermal damage. because shortened pulse durations also decrease therma
We report diode pumped continuous-wave (CW) laser performance achieved with two types of composite Nd:LuVO 4 crystals operating at 1.06 ΞΌm. The maximum output power of 17.2 W was obtained with an optical conversion efficiency of 47.3% with respect to the incident pump power of 36.4 W, and the corres
The purpose of this study is to compare the optical transmission of the pulsed gold vapor laser (628 nm) to that of the continuous wave argon-pumped dye laser (630 nm) in a homogenous tissue model. Gluteal muscle was taken from a rabbit, and sections of varying thicknesses were made. The tissue samp