## Abstract ## Purpose To compare the signal characteristics and bolus dynamics of 1.0 M gadobutrol and 0.5 M Gd‐DTPA for time‐resolved, three‐dimensional, contrast‐enhanced (CE) MRA of the upper torso. ## Materials and Methods Ten healthy volunteers were examined with time‐resolved three‐dimens
Comparison of 0.5-M Gd-DTPA with 1.0-M gadobutrol for magnetic resonance angiography of the supplying arteries of the spinal cord in thoracoabdominal aortic aneurysm patients
✍ Scribed by Robbert J. Nijenhuis; Suzanne Gerretsen; Tim Leiner; Michael J. Jacobs; Jos M.A. van Engelshoven; Walter H. Backes
- Publisher
- John Wiley and Sons
- Year
- 2005
- Tongue
- English
- Weight
- 475 KB
- Volume
- 22
- Category
- Article
- ISSN
- 1053-1807
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Purpose
To prospectively compare 0.5‐M gadopentetate dimeglumine (Gd‐DTPA) with 1.0‐M gadobutrol for contrast‐enhanced magnetic resonance angiography (CE‐MRA) of the blood supplying arteries of the spinal cord in patients referred for open surgical repair of a thoracoabdominal aortic aneurysm (TAAA).
Materials and Methods
A total of 11 patients with a TAAA underwent two three‐dimensional CE‐MRA exams of the aorta, segmental arteries (SAs), artery of Adamkiewicz (AKA), and anterior spinal artery (ASA). Imaging was performed on two separate occasions using Gd‐DTPA and gadobutrol as contrast agents at 0.3 mmol/kg. Images were evaluated by measuring signal‐to‐noise (SNR) and contrast‐to‐noise (CNR) ratios and were judged for different image quality criteria by two blinded observers.
Results
In all patients both CE‐MRA exams were of sufficient image quality to detect the AKA and ASA. No significant differences in SNR and CNR were observed between the two contrast agents. According to the observers, no significant differences in subjective image quality were found.
Conclusions
Using both contrast agents it was possible to visualize the ultrasmall spinal cord arteries in all cases. The use of the 1.0‐M contrast agent did not improve image quality of CE‐MRA images of the blood supplying arteries of the spinal cord compared to the 0.5‐M contrast agent. J. Magn. Reson. Imaging 2005;22:136–144. © 2005 Wiley‐Liss, Inc.