๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Comparison between muon and positron images using imaging plates

โœ Scribed by Masao Doyama; Yoshiaki Kogure; Miyoshi Inoue; Toshikazu Kurihara; Xingzhong Cao; Kusuo Nishiyama; Koichiro Shimomura


Publisher
Elsevier Science
Year
2009
Tongue
English
Weight
687 KB
Volume
600
Category
Article
ISSN
0168-9002

No coin nor oath required. For personal study only.

โœฆ Synopsis


A muon beam intensity distribution perpendicular to the beam has been obtained using imaging plates that are commonly used in X-ray science, medical analysis, and transmission electron microscopy. The resolution of the imaging plates depends on the resolution of the imaging plate reader. We have used BAS-TR2025 imaging plates and a Bio-Imaging Analyzer (BAS-2500 or BAS-3000). The positional resolution is 50 mm ร‚ 50 mm. When the beam is one kind, because a coincidence measurement is not necessary, the muon distribution perpendicular to the beam is taken in a very short time, and the spatial resolution is 50 mm ร‚ 50 mm. Such a resolution cannot be obtained by the usual muon measuring method. This is quite convenient to adjust muon beams. When FLA-8000 or FLA-9000 is used, the resolution can be improved to 10 mm ร‚ 10 mm. Such an intensity resolution of muon beams could not be imagined without using imaging plates. Obtained transmission muon images are also presented. This can be used as a non-destructive test.


๐Ÿ“œ SIMILAR VOLUMES


Transmission positron images using imagi
โœ Masao Doyama; A. Kogure; M. Inoue; T. Kurihara; X. Cao; M. Matsuya; T. Yoshiie; ๐Ÿ“‚ Article ๐Ÿ“… 2008 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 565 KB
Comparison between black and white backg
โœ Roger C. Sanders ๐Ÿ“‚ Article ๐Ÿ“… 1980 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 235 KB

## Abstract Two hundred and three studies were selected from approximately 5,000 abdominal examinations where comparable images obtained at the same level with both a black and a white background were available. The ease with which liver metastatic lesions, ducts and vessels in the liver and pancre

Comparison of functional brain PET image
โœ S.B. Sobottka; J. Bredow; B. Beuthien-Baumann; G. Reiss; G. Schackert; R. Steinm ๐Ÿ“‚ Article ๐Ÿ“… 2002 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 625 KB

Objective: Knowledge about the spatial localization of eloquent brain areas is essential for resecting lesions in the vicinity of these areas. The classical approach is to perform surgery on the awake patient under local anesthesia using brain-mapping techniques. As an alternative, the location of e