## Abstract In this investigation the electrochemical behaviour of the Tiโ13Nbโ13Zr, Tiโ6Alโ4V and Tiโ6Alโ7Nb alloys, for application as implant materials was evaluated in Hanks' solution by electrochemical techniques. The alloys were immersed in this solution for 410 days and periodically they wer
Comparative Evaluation on the In Vitro Biological Performance of Ti45Al8.5Nb Intermetallic with Ti6Al4V and Ti6Al7Nb Alloys
โ Scribed by Huafang Li; Yufeng Zheng; Junpin Lin
- Publisher
- John Wiley and Sons
- Year
- 2011
- Tongue
- English
- Weight
- 954 KB
- Volume
- 13
- Category
- Article
- ISSN
- 1438-1656
No coin nor oath required. For personal study only.
๐ SIMILAR VOLUMES
## Abstract The impairment of skeletal muscle microcirculation by a biomaterial may have profound consequences. Due to excellent physical and corrosion characteristics, CoCrMoโ, Tiโ6Alโ4Vโ, and Tiโ6Alโ7Nbโalloys are commonly used in orthopedic surgery. Yet concern has been raised with regard to the
## Abstract __In vitro__ studies of Tiโ6Alโ7Nb and Tiโ5Alโ2Nbโ1Ta alloys were carried out by treating the specimens with 10__M__ NaOH at 60ยฐC for 24 h and subsequently heatโtreated at 600ยฐC for 1 h. After the alkali and heat treatments, and on subsequent soaking in simulated body fluid (SBF), the m
The electrochemical behavior of Ti-6Al-7Nb alloy with and without plasma-sprayed hydroxyapatite (HA) coating was investigated in Hank's balanced salt solution at 37 degrees C. This behavior was evaluated by analyzing both corrosion potential variation with time curves and potentiodynamic polarizatio