Comparability of different methods of retrospective exposure assessment of metals in manufacturing industries
β Scribed by Benjamin A. Rybicki; Christine Cole Johnson; Edward L. Peterson; Gene X. Kortsha; Jay M. Gorell
- Publisher
- John Wiley and Sons
- Year
- 1997
- Tongue
- English
- Weight
- 71 KB
- Volume
- 31
- Category
- Article
- ISSN
- 0271-3586
No coin nor oath required. For personal study only.
β¦ Synopsis
Many occupational case-control studies have relied on either self-report or exposure assessment based on job titles linked to a job exposure matrix (JEM) as opposed to the generally considered more accurate, but labor intensive, method of expert review of job histories. Our study examined the comparability of these different methods in assessing occupational exposure to the metals copper (Cu), lead (Pb), and iron (Fe) in manufacturing industries. Subjects were older people from a case-control study of a neurologic disease, and consisted of 188 individuals (72% male, 85% white) who had worked an average of 22.4 years in the manufacturing industry. An industrial hygienist review (IHR) of occupational history data from a comprehensive questionnaire was used as the reference method. The percent agreement (%A), sensitivity (SE), and specificity (SP) for direct self-report of metal exposures were: Cu, %A 5 94.6, SE 5 83.6, SP 5 96.1; Pb, %A 5 91.9, SE 5 72.5, SP 5 93.5; and Fe, %A 5 82.7, SE 5 64.5, SP 5 88.1. Using the National Institute for Occupational Safety and Health (NIOSH) JEM, we analyzed the jobs of 115 of the 188 study subjects who had all their jobs listed in the JEM. Exposure assessment based on the NIOSH JEM compared with the IHR resulted in greater misclassification relative to direct self-report: Cu, %A 5 81.5, SE 5 21.2, SP 5 89.2; Pb, %A 5 86.0, SE 5 0.0, SP 5 92.6; and Fe, %A 5 69.2, SE 5 15.5, SP 5 86.4. For all three study metals, combining the information from both direct self-report and the JEM did not improve upon the results compared with direct self-report alone. Due to the complex nature of metal exposure assessment, we suggest using an expert review of job histories whenever possible to minimize potential misclassification. Am.
π SIMILAR VOLUMES
## Abstract __Objective__: In 2005, the Taiwan Institute of Occupational Safety and Health started an onβsite consulting program for the medical supplies manufacturing industry, which use ethylene oxide (EO) as a sterilant, with the goal of enhancing occupational hygiene practices and controlling E
In recent years there has been increasing interest in radio-epidemiological techniques to retrospectively measure the radon dose exposure by determining the activity of 210 Pb, the longest-lived 222 Rn progeny, in glass surface layers. In this study the diffusion of 39 keV 209 Pb + ions implanted in