Colour velocity flow measurement: In vitro validation and application to human carotid arteries

✍ Scribed by Colin R. Deane; Hugh S. Markus


Book ID
104324619
Publisher
Elsevier Science
Year
1997
Tongue
English
Weight
661 KB
Volume
23
Category
Article
ISSN
0301-5629

No coin nor oath required. For personal study only.

✦ Synopsis


Ultrasound measurement of volume blood flow is potentially useful for many clinical situations, yet practical implementation and use are restricted by the many instrumentation and blood fiow limitations that can arise. Colour velocity imaging offers a number of theoretical advantages over methods b&sed on duplex imaging. We evaluated a colour velocity flow measurement system (CVI-Q, Philips) both in a flow phantom and in viva in the extracranial carotid arteries of normal volunteers. Over a range of constant (50-1200 ml/min) and pulsatile (92-366 mI/min) flows and using both steered and unsteered beams with beam angles of 30" and 40", errors usually within 5% were obtained for constant flow and within 10% for pulsatile flow. However, with a beam angle of 70", higher errors of 20% were obtained for pulsatiile flow. The reproducibility of flow measurements made using both anterior and posterior-lateral scanning approaches was determined in the common (CCA), internal (ICA) and external carotid (ECA) arteries of 18 volunteers. A greater reproducibility was found using the posterior-lateral approach (CCA 6.27%; ICA 9.8%), and mean (SD) flow values were 376 ml/min in the CCA and 255 mI/min in the ICA. The ratio of (ICA + ECA)/CCA flow calculated for each subject individually was mean (SD) 0.95 (0.11). Insonation from an anterior approach resulted in lower reproducibility and lower flow values. In con&&on, colour flow velocity imaging allows repeatable reproducible measurements of CCA and ICA flow, but results are optimal if a posterior-lateral scanning approach is used. 0 1997 World Federation for Ultrasound in Medicine & Biology.


πŸ“œ SIMILAR VOLUMES


Carotid and vertebral artery blood flow
✍ Hugo G. Bogren; Michael H. Buonocore; Wei-Zhong Gu πŸ“‚ Article πŸ“… 1994 πŸ› John Wiley and Sons 🌐 English βš– 767 KB

## Abstract The goal of the study was to establish normal carotid artery flow rates in left‐handed and right‐handed individuals as a standard against which patients with carotid artery disease could be compared. Antegrade and retrograde flow were measured in the ascending aorta, in the right and le