๐ SIMILAR VOLUMES
## Abstract Objective: The purpose of this study was to describe our experience concerning the use of covered Cheatham Platinum (CP) stent in patients with fenestrated total cavopulmonary connection (TCPC). Background: Closure of TCPC fenestrations has been achieved by utilizing different devices d
We report the successful percutaneous closure of a large coronary artery fistula from the obtuse marginal artery to the right ventricle in an 8-month-old boy using the Amplatzer duct occluder. The device was positioned and deployed via the venous system, using a guidewire that had been advanced via