A simple method of identifying "rst order plus time delay transfer function model is proposed for unstable systems. The method is based on a single experiment on a closed-loop system with a step change in the set point of a PI or PID controller. The step response and derived analytical formulae are used to calculate the steady-state gain, time delay and time constant of the unstable system. Simulation results are given for transfer function models and on nonlinear model equation of an unstable bioreactor. The identi"ed model parameters and/or the designed PID controllers settings are compared with those of the exact or the linearized model used.
๐ SIMILAR VOLUMES
We compare two methods of estimating transfer functions from observed records of input and output when the output contains an additive noise component of unknown statistical structure. The two methods correspond to (a) a "weighted least-squares" estimate (/fl) and (b) a "simple least-squares" estima
## We convert the closed-loop identification of nonlinear time-varying plants, with high signal-to-noise ratio, to an open-loop identification problem of an associated Youla-Kucera parameter. The plant must be stabilizable by a known linear, possibly time-varying controller.
Experiment designs are considered which allow the possibility that the true system cannot be exactly described within the chosen model set.