𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Cine magnetic resonance microscopy of the rat heart using cardiorespiratory-synchronous projection reconstruction

✍ Scribed by Anja C.S. Brau; Laurence W. Hedlund; G. Allan Johnson


Publisher
John Wiley and Sons
Year
2004
Tongue
English
Weight
702 KB
Volume
20
Category
Article
ISSN
1053-1807

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Purpose

To tailor a cardiac magnetic resonance (MR) microscopy technique for the rat that combines improvements in pulse sequence design and physiologic control to acquire high‐resolution images of cardiac structure and function.

Materials and Methods

Projection reconstruction (PR) was compared to conventional Cartesian techniques in point‐spread function simulations and experimental studies to evaluate its artifact sensitivity. Female Sprague‐Dawley rats were imaged at 2.0 T using PR with direct encoding of the free induction decay. Specialized physiologic support and monitoring equipment ensured consistency of biological motion and permitted synchronization of imaging with the cardiac and respiratory cycles.

Results

The reduced artifact sensitivity of PR offered improved delineation of cardiac and pulmonary structures. Ventilatory synchronization further increased the signal‐to‐noise ratio by reducing inter‐view variability. High‐quality short‐axis and long‐axis cine images of the rat heart were acquired with 10‐msec temporal resolution and microscopic spatial resolution down to 175 μm × 175 μm × 1 mm.

Conclusion

Integrating careful biological control with an optimized pulse sequence significantly limits both the source and impact of image artifacts. This work represents a novel integration of techniques designed to support measurement of cardiac morphology and function in rodent models of cardiovascular disease. J. Magn. Reson. Imaging 2004;20:31–38. © 2004 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Time-resolved undersampled projection re
✍ Jiang Du; Aiming Lu; Walter F. Block; Francis J. Thornton; Thomas M. Grist; Char 📂 Article 📅 2005 🏛 John Wiley and Sons 🌐 English ⚖ 428 KB

## Abstract The hybrid projection reconstruction (PR) imaging provides high temporal resolution through an undersampled PR acquisition for the in‐plane dimensions and Cartesian slice encoding for the through‐plane dimension. The undersampling of projection data introduces streak artifact, which may

Magnetic resonance imaging of perfusion
✍ Donald S. Williams; Donald J. Grandis; Weiguo Zhang; Alan P. Koretsky 📂 Article 📅 1993 🏛 John Wiley and Sons 🌐 English ⚖ 615 KB

## Abstract Measurement of regional myocardial perfusion is important for the diagnosis and treatment of coronary artery disease. Currently used methods for the measurement of myocardial tissue perfusion are either invasive or not quantitative. Here, we demonstrate a technique for the measurement o