Characteristics of the double inlet pulse tube
โ Scribed by P.C.T. de Boer
- Publisher
- Elsevier Science
- Year
- 2003
- Tongue
- English
- Weight
- 481 KB
- Volume
- 43
- Category
- Article
- ISSN
- 0011-2275
No coin nor oath required. For personal study only.
โฆ Synopsis
The performance of the double inlet pulse tube (DIPT) is analyzed using a linearized model that takes account of the void volume of the regenerator. The maximum rate of refrigeration obtainable with the regenerator is determined as a function of frequency and void volume. This rate can be achieved by a DIPT with infinitely large reservoir volume. Corrections resulting from a finite reservoir volume are important only at low frequency. The coefficient of performance of a DIPT with optimized rate of refrigeration is less than half of the thermodynamic maximum. The results obtained for the DIPT are compared with corresponding results for the optimized orifice pulse tube refrigerator (OPTR). The large improvements in performance obtained with the DIPT over the OPTR are due primarily to an increase in the pulse tube pressure. The maximum rate of refrigeration decreases as the temperature at the cold side decreases. This is caused primarily from the resulting decrease in cold side flow rate. At given temperature ratio, addition of the second inlet reduces the flow rate through the regenerator over a range of intermediate frequencies.
๐ SIMILAR VOLUMES
An analytic equation of the mass flow rate through the bypass of double-inlet pulse tube refrigerators was obtained by an analysis of the pressure drop in the regenerator. The work loss through the bypass is discussed based on this equation. The work loss decreases with the increase of the void volu
This paper describes experimental results on the double-inlet pulse tube refrigerator. The effects of varying the amplitudes and phase difference of the pressure wave and mass flow are presented and discussed.
This paper presents the test results of the internal process of a double inlet pulse tube refrigerator, the main objective is to reveal the effects of some important parameters , such as by-pass valve and orifice opening, operating frequency and mean pressure, on the amplitude shift and phase shift
A mechanical support system is described for a space-borne 3He refrigerator that relies on Kevlar 29 braided cords to achieve thermal isolation at temperatures ranging from 0.3 to 40 K. Measurements of the Young's modulus, tensile strength, creep and thermal conductivity of Kevlar cords at room and
Through analyzing phase relation between pressures and flow characteristics of double-inlet and multi-bypass, mechanism of double-inlet to lower the temperature of pulse tube refrigerator is proposed. Then another proposal is put forward to replace the low temperature multi-bypass valve, which is an