Characteristics of lightning surges observed at 77 kV substations

โœ Scribed by Toshiaki Ueda; Masayuki Yoda; Iwao Miyachi


Publisher
John Wiley and Sons
Year
1998
Tongue
English
Weight
237 KB
Volume
124
Category
Article
ISSN
0424-7760

No coin nor oath required. For personal study only.

โœฆ Synopsis


In order to improve power supply reliability, it is necessary to prevent lightning faults in transmission lines and substation apparatus. However, faults are caused occasionally in lower-voltage power systems, particularly at the 77 kV level. The governing factor for insulation strength of substation apparatus is the lightning impulse voltage, and it is necessary to know the voltage level and distribution in a substation caused by lightning surges in order to investigate rational insulation coordination. For this purpose, the authors measured lightning surges at two 77 kV conventional substations from 1990 to 1993. In this paper, the characteristics of induced lightning surges and back flashover lightning surges are described. Comparisons of related surge voltages at two substations, the power line phases in grounding faults, and the equivalent capacitance of the substations are also discussed.


๐Ÿ“œ SIMILAR VOLUMES


Characteristics of lightning surges obse
โœ Toshiaki Ueda; Masayuki Yoda; Iwao Miyachi ๐Ÿ“‚ Article ๐Ÿ“… 1998 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 757 KB

In order to improve power supply reliability, it is necessary to prevent lightning faults in transmission lines and substation apparatus. However, faults are caused occasionally in lower-voltage power systems, particularly at the 77 kV level. The governing factor for insulation strength of substatio

Observation of lightning at 500-kV trans
โœ Katsuhiro Ouchi; Takehiko Kikuchi; Akio Ozawa; Yoshihisa Tamura; Masaki Nakada ๐Ÿ“‚ Article ๐Ÿ“… 2000 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 987 KB

We investigated the phenomenon of lightning strokes on 500-kV transmission lines from 1984 to 1993. The investigation covered the recording of lightning paths by still cameras and measurements of lightning current at the lower part of transmission tower on 31 towers, over a 12.7-km-long section of t

Characteristics of nearby lightning disc
โœ A.V. Shvets; A.P. Nickolaenko; M. Hayakawa ๐Ÿ“‚ Article ๐Ÿ“… 1997 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 743 KB

## An analysis is performed of the parameters of nearby lightning discharges. Vertical electric and two perpendicular horizontal magnetic field components were recorded in the frequency range from 300 Hz to 13 kHz. Observations were performed at Singapore on 26 February, 1991. Data were stored in