A centrifugal pump used for c~rculatmg hqutd hehum through a large superconducting magnet was tested The performance of the pump was measured during a magnet coohng test The pump operated well wtth atyptcal capacity of 400 dm 3 h -~ (Ap = 0 3 kg cm-2) at 20000 rpm An analys~s of the test results ~s
Centrifugal pump performance calculation for homogeneous suspensions
β Scribed by L. J. W. Graham; L. Pullum; P. Slatter; G. Sery; M. Rudman
- Publisher
- John Wiley and Sons
- Year
- 2009
- Tongue
- English
- Weight
- 505 KB
- Volume
- 87
- Category
- Article
- ISSN
- 0008-4034
No coin nor oath required. For personal study only.
β¦ Synopsis
Abstract
Centrifugal pumps are widely used for transporting suspensions, but their head performance is derated when nonβNewtonian fluids and/or coarse solids are present. Some head deration methods are available for high viscosity Newtonian fluids, Bingham plastic fluids and for coarse solids in water. This paper presents a modification of the Hydraulic Institute head deration method that is suitable for any homogeneous nonβNewtonian rheology. A modification of the Walker and Goulas method is also considered. Possible anomalous behaviour of kaolin slurries in centrifugal pumps is discussed.
π SIMILAR VOLUMES