## Background and Objectives : Traumatic transection of a peripheral nerve is inherently associated with the development of neuroma at the end of the proximal stump, often leading to therapyresistant pain. This study was designed to evaluate whether the neodymium:yttrium aluminum garnet (Nd:YAG) la
Carbon dioxide laser-assisted nerve repair: Effect of solder and suture material on nerve regeneration in rat sciatic nerve
✍ Scribed by Tomas Menovsky; Johan F. Beek
- Publisher
- John Wiley and Sons
- Year
- 2003
- Tongue
- English
- Weight
- 224 KB
- Volume
- 23
- Category
- Article
- ISSN
- 0738-1085
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
In order to further improve and explore the role of lasers for nerve reconstruction, this study was designed to investigate regeneration of sharply transected peripheral nerves repaired with a CO~2~ milliwatt laser in combination with three different suture materials and a bovine albumin protein solder as an adjunct to the welding process. Unilateral sciatic nerve repair was performed in 44 rats. In the laser group, nerves were gently apposed, and two stay sutures (10‐0 nylon, 10‐0 polyglycolic acid, or 25‐μm stainless steel) were placed epi/perineurially. Thereafter, the repair site was fused at 100 mW with pulses of 1.0 s. In the subgroup of laser‐assisted nerve repair (LANR), albumen was used as a soldering agent to further reinforce the repair site. The control group consisted of nerves repaired by conventional microsurgical suture repair (CMSR), using 4–6 10‐0 nylon sutures. Evaluation was performed at 1 and 6 weeks after surgery, and included qualitative and semiquantitative light microscopy. LANR performed with a protein solder results in a good early peripheral nerve regeneration, with an optimal alignment of nerve fibers and minimal connective tissue proliferation at the repair site. All three suture materials produced a foreign body reaction; the least severe was with polyglycolic acid sutures. CMSR resulted in more pronounced foreign‐body granulomas at the repair site, with more connective‐tissue proliferation and axonal misalignment. Furthermore, axonal regeneration in the distal nerve segment was better in the laser groups. Based on these results, CO~2~ laser‐assisted nerve repair with soldering in combination with absorbable sutures has the potential of allowing healing to occur with the least foreign‐body reaction at the repair site. Further experiments using this combination are in progress. © 2003 Wiley‐Liss, Inc. MICROSURGERY 23:109–116 2003
📜 SIMILAR VOLUMES
## Abstract ## Background and Objective Post‐traumatic nerve repair is still a challenge for rehabilitation. It is particularly important to develop clinical protocols to enhance nerve regeneration. The present study investigated the effects of 660 and 780 nm low‐level laser therapy (LLLT) using d