The particle identification performance of the HERA-B RICH is presented. The results are based on the measured data acquired in the last running period 2002-2003.
Calibration of the mirror system in the HERA-B RICH
✍ Scribed by Marko Starič; Peter Križan
- Publisher
- Elsevier Science
- Year
- 2008
- Tongue
- English
- Weight
- 275 KB
- Volume
- 586
- Category
- Article
- ISSN
- 0168-9002
No coin nor oath required. For personal study only.
✦ Synopsis
The mirror system of the HERA-B ring imaging Cherenkov (RICH) counter consists of two spherical and two planar mirrors, composed of altogether 116 mirror segments. Analysis of displacements of the Cherenkov ring center relative to the charged particle track, for given spherical-planar segment pairs, leads to accurate information regarding the orientation of individual mirror segments. The method for mirror calibration is described and the effect of applying the required corrections on the Cherenkov angle resolution of the HERA-B RICH is discussed.