✦ Synopsis


The calibration of nonlocal models which contain an internal length has been among the major issues conditioning the implementation of this kind of failure models. Direct calibration from uniaxial testing, where the state of strain remains homogeneous throughout the specimen, is impossible. The softening law is not directly accessible because the strains cannot remain homogeneous during the entire test. In the absence of local information on the displacement field and on micro cracking in the fracture process zone, the calibration has to rely on inverse analysis. This paper presents such a procedure based on three point bend size effect tests on notched specimens. The complete load deflection curves are used for the identification of the constitutive relations. Manual calibration is discussed first. It is emphasised that calibration on the load deflexion curve from a single experiment is not objective. We show that Bazant's size effect law, which is related to peak loads only, may serve as a helpful guide to reach the closest fit. Then, automatic calibration is described. An optimal set of model parameters can be obtained within a reasonable number of iterations.


📜 SIMILAR VOLUMES


Continuous model for software reliabilit
✍ K Sawada; H Sandoh 📂 Article 📅 2000 🏛 Elsevier Science 🌐 English ⚖ 422 KB

This study proposes a continuous model for software reliability demonstration testing, which takes the damage size of software failures into consideration. In the proposed procedure, the software being tested is accepted if the number of software failures does not exceed a prespecified value, s and

Determination of suspended particulate m
✍ J. Pfannkuche; A. Schmidt 📂 Article 📅 2003 🏛 John Wiley and Sons 🌐 English ⚖ 285 KB

## Abstract Measurements of suspended particulate matter concentration and turbidity point towards the possibility of a site‐specific algorithm (SPM), relating SPM to nephelometric turbidity units (NTU). In this paper regression models are presented that account for changes in the relationship of S

Size, shape, and composition of wear par
✍ Catelas, Isabelle ;Bobyn, J. Dennis ;Medley, John B. ;Krygier, Jan J. ;Zukor, Da 📂 Article 📅 2003 🏛 John Wiley and Sons 🌐 English ⚖ 257 KB

## Abstract There has been a revived interest in metal–metal total hip replacements because of their potential for improved wear performance compared with conventional metal–polyethylene implants. The aim of the present study was to characterize metal wear particles isolated from metal–metal hip si