𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Bone response to unloaded and loaded titanium implants with a sandblasted and acid-etched surface: A histometric study in the canine mandible

✍ Scribed by Cochran, D. L. ;Schenk, R. K. ;Lussi, A. ;Higginbottom, F. L. ;Buser, D.


Publisher
John Wiley and Sons
Year
1998
Tongue
English
Weight
545 KB
Volume
40
Category
Article
ISSN
0021-9304

No coin nor oath required. For personal study only.

✦ Synopsis


Many dental clinical implant studies have focused on the success of endosseous implants with a variety of surface characteristics. Most of the surface alterations have been aimed at achieving greater bone-to-implant contact as determined histometrically at the light microscopic level. A previous investigation in non-oral bone under shortterm healing periods (3 and 6 weeks) indicated that a sandblasted and acid-etched titanium (SLA) implant had a greater bone-to-implant contact than did a comparablyshaped implant with a titanium plasma-sprayed (TPS) surface. In this canine mandible study, nonsubmerged implants with a SLA surface were compared to TPS-coated implants under loaded and nonloaded conditions for up to 15 months. Six foxhound dogs had 69 implants placed in an alternating pattern with six implants placed bilaterally in each dog. Gold crowns that mimicked the natural occlusion were fabricated for four dogs. Histometric analysis of bone contact with the implants was made for two dogs after 3 months of healing (unloaded group), 6 months of healing (3 months loaded), and after 15 months of healing (12 months loaded). The SLA implants had a significantly higher (p < 0.001) percentage of bone-to-implant contact than did the TPS implants after 3 months of healing (72.33 ± 7.16 versus 52.15 ± 9.19; mean ± SD). After 3 months of loading (6 months of healing) no significant difference was found between the SLA and TPS surfaced implants (68.21 ± 10.44 and 78.18 ± 6.81, respectively). After 12 months of loading (15 months of healing) the SLA implants had a significantly greater percentage (p < 0.001) of bone-to-implant contact than did the TPS implants (71.68 ± 6.64 and 58.88 ± 4.62, respectively). No qualitative differences in bone tissue were observed between the two groups of implants nor was there any difference between the implants at the clinical level. These results are consistent with earlier studies on SLA implants and suggest that this surface promotes greater osseous contact at earlier time points compared to TPS-coated implants.


📜 SIMILAR VOLUMES


Bone response to endosseous titanium imp
✍ Jin-Woo Park; Il-Sung Jang; Jo-Young Suh 📂 Article 📅 2008 🏛 John Wiley and Sons 🌐 English ⚖ 441 KB

## Abstract This study evaluated the effects of the addition of oxide structure with submicron‐scale porous morphology on the periimplant bone response around titanium (Ti) implants with microroughened surfaces. Hydroxyapatite‐blasted Ti implants with (experimental) and without (control) a porous o