Bone growth in rapid prototyped porous titanium implants
β Scribed by M. A. Lopez-Heredia; E. Goyenvalle; E. Aguado; P. Pilet; C. Leroux; M. Dorget; P. Weiss; P. Layrolle
- Publisher
- John Wiley and Sons
- Year
- 2008
- Tongue
- English
- Weight
- 443 KB
- Volume
- 85A
- Category
- Article
- ISSN
- 1549-3296
No coin nor oath required. For personal study only.
β¦ Synopsis
Abstract
Two porous titanium implants with a pore size diameter of 800 and 1200 ΞΌm (Ti800 and Ti1200) and an interconnected network were manufactured using rapid prototyping. Their dimensions and structure matched those of the computer assisted design. The porosity of the implants was around 60%. Their compressive strength and Young's modulus were around 80 MPa and 2.7 GPa, respectively. These values are comparable to those of cortical bone. The implants were implanted bilaterally in the femoral epiphysis of 15 New Zealand White rabbits. After 3 and 8 weeks, abundant bone formation was found inside the rapid prototyped porous titanium implants. For the Ti1200 implants, bone ingrowth was (23.9 Β± 3.5)% and (10.3 Β± 2.8)%, respectively. A significant statistical difference (p < 0.05) was found for bone ingrowth in the Ti1200 between the two delays. The percentage of bone directly apposited on titanium was (35.8 Β± 5.4)% and (30.5 Β± 5.0)%. No significant difference was found for boneβimplant contact between the different time periods and pore sizes. This work demonstrates that manufacturing macroporous titanium implants with controlled shape and porosity using a rapid prototyping method is possible and that this technique is a good candidate for orthopedic and maxillofacial applications. Β© 2007 Wiley Periodicals, Inc. J Biomed Mater Res, 2008
π SIMILAR VOLUMES
## Abstract The effect of __in vivo__ electrical stimulation on the interfacial strength between porous titanium implants and cortical bone was studied in mongrel dogs. The interfacial shear strength of the stimulated implants was consistently greater than that of controls. No difference could be o
A 5 x 5 x 1-mm uncoated porous nickel-titanium (nitinol) implant was placed 4 mm to either side of the midsection of the frontal bone and 4 mm anterior to the coronal suture of the cranial bone of New Zealand White rabbits. In the other frontal location, a 5 x 5 x 1-mm coralline hydroxyapatite (HA)
Fourteen titanium porous-coated implants with a cylindrical shape (length 22 mm and diameter 5\_+0.3 mm) were prepared. Bead size was 250-350 gm. Seven implants were plasma-sprayed with hydroxyapatite and the other seven remained uncoated. Implants, both hydroxyapatite-coated and uncoated, were rand
Bone ingrowth into weight-bearing porous fiber Ti-6A1-4V implants in rat tibias was assessed for the amount, composition, and mineralization rate 3, 12, and 26 weeks after implantation. The data were compared with the ipsiand contralateral metaphyseal controls and related to the ultimate bending str