The opinions contained herein are solely those of the authors and should not be interpreted as representing federal policies.
Biocompatibility of total joint replacements: A review
✍ Scribed by Stuart B. Goodman; Enrique Gómez Barrena; Michiaki Takagi; Yrjo T. Konttinen
- Publisher
- John Wiley and Sons
- Year
- 2009
- Tongue
- English
- Weight
- 378 KB
- Volume
- 90A
- Category
- Article
- ISSN
- 1549-3296
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Total joint replacement is one of the most clinically successful, cost‐effective surgical procedures. These operations have been shown to improve pain, function and mobility in patients with end‐stage arthritis. However, joint replacements that will allow full, unrestricted, high impact activities and last the patient's lifetime have not yet been devised. This is due to biocompatibility issues related to material science, biomechanics, and host responses. In this review, three issues that are highly pertinent to biocompatibility of joint replacements are examined. These topics include how implants initially osseointegrate within bone, potential adverse effects of byproducts of wear that can lead to aseptic loosening and perprosthetic osteolysis, and the potential for new bearing surfaces to extend the lifetime of implants. A clear understanding of these important issues will facilitate the development of novel strategies to improve the longevity and function of implants for joint replacement in the future. © 2008 Wiley Periodicals, Inc. J Biomed Mater Res, 2009
📜 SIMILAR VOLUMES
## Abstract Modification of ultrahigh‐molecular‐weight polyethylene (UHMWPE) consisting of a combination of γ irradiation and subsequent thermal treatment has been performed in order to investigate the reasultant changes to its supramolecular structure. In the first step the polymer was irradiated
Improved understanding of the clinical outcomes of orthopedic implants requires the study of implants at the end of their service life. Previous studies focused on the retrieval of so-called failed implants during surgical revision. Interest is now moving to the study of successful implants, which a
## Abstract Surface characterization was performed to evaluate the surface condition of an uncoated cobalt alloy disc (control), and discs with medium and thick boron coatings for total joint articulating surfaces. Discs were characterized by scanning electron microscopy before and after dissolutio
## Abstract A case of osseous reankylosis occurred after total replacement of one hip in a patient having ankylosing spondylitis. Not only did the ankylotic disease involve the vertebral column, but the severity of this process had been manifest through osseous ankylosis of bilateral cup arthroplas
## Abstract ## Objective To explore patients' perspectives of need for total joint replacement associated with decision making in orthopaedic consultations for hip or knee osteoarthritis. ## Methods Twenty‐six orthopaedic consultations in 3 UK hospitals were observed and audio recorded, and semi