โœฆ Synopsis


The results of an experimental study on the behaviour of azeotropic ternary refrigerant mixtures in heated suction accumulator are presented. The experiment set up was composed of a fully instrumented air-source heat pump with a capacity of 36 000 BTUH and equipped with a heated suction accumulator.

Standard test conditions were used at the condenser inlet; however, the refrigerant temperatures were varied at the evaporator entrance from 2 to !403C, to simulate various conditions encountered in extreme air-source heat pump applications. The primary parameters observed during the course of this study were mass #ux, heat #ux, and quality, evaporator and condenser thermal capacities, and power consumed and pressure ratios for the azeotropic refrigerant mixtures under investigation.

The test results showed that heated suction accumulators enhance the evaporation of the more volatile component of ternary azeotropic refrigerant mixtures. Thus, increasing the mixture thermal capacity as well as the coe$cient of performance (COP). Furthermore, experiments have also shown capacity increases of 27% with heated accumulator over unheated accumulator at !303C outside air temperatures.


๐Ÿ“œ SIMILAR VOLUMES


Effects of annealing in ABS ternary blen
โœ B. K. Kim; L. K. Yoon; X.-M. Xie ๐Ÿ“‚ Article ๐Ÿ“… 1997 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 483 KB ๐Ÿ‘ 2 views

Acrylonitrile-butadiene-styrene terpolymer (ABS)/poly(methyl methacrylate) (PMMA) binary and ABS/PMMA/polycarbonate (PC) ternary blends were prepared using a corotating twin-screw extruder. Blend samples were annealed in a constant-temperature (215 and 225ะŠC) hydraulic press up to 85 min. The change

Experimental performance of ternary solu
โœ R. M. Barragan; V. M. Arellano; C. L. Heard; R. Best ๐Ÿ“‚ Article ๐Ÿ“… 1998 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 233 KB ๐Ÿ‘ 1 views

In this work, results from experiments with ternary solutions in an absorption heat transformer are presented. The experiments were performed under controlled conditions using water/lithium chloride/zinc chloride and water/calcium chloride/zinc chloride solutions as working pairs. The results showed