Current studies of bearing capacity for shallow foundations tend to rely on the hypothesis of an isolated footing. In practice a footing is never isolated; it is mostly in interaction with other footings. This paper focuses on a numerical study using the finite-difference code Fast Lagrangian Analys
Bearing capacity of two interfering footings
β Scribed by Jyant Kumar; K. M. Kouzer
- Publisher
- John Wiley and Sons
- Year
- 2008
- Tongue
- English
- Weight
- 434 KB
- Volume
- 32
- Category
- Article
- ISSN
- 0363-9061
- DOI
- 10.1002/nag.625
No coin nor oath required. For personal study only.
β¦ Synopsis
By using an upper bound limit analysis in conjunction with finite elements and linear programming, the ultimate bearing capacity of two interfering rough strip footings, resting on a cohesionless medium, was computed. Along all the interfaces of the chosen triangular elements, velocity discontinuities were employed. The plastic strains were incorporated using an associated flow rule. For different clear spacing (S) between the two footings, the efficiency factor ( ) was determined, where is defined as the ratio of the failure load for a strip footing of given width in the presence of the other footing to that of a single isolated strip footing having the same width. The value of at S/B = 0 becomes equal to 2.0, and the maximum occurs at S/B = S cr /B. For S/B S cr /B, the ultimate failure load for a footing becomes almost half that of an isolated footing having width (2B + S), and the soil mass below and in between the two footings deforms mainly in the downward direction. In contrast, for S/B>S cr /B, ground heave was noticed along both the sides of the footing. As compared to the available theories, the analysis provides generally lower values of for S/B>S cr /B.
π SIMILAR VOLUMES
This paper utilizes a finite difference code FLAC to study bearing capacity factor N c for ring footings in cohesionless, frictional and ponderable soil. The present soil model employs Mohr-Coulomb yield criterion and associative flow rule. The value of N c is found to decrease significantly with an
For a strip footing under axial loading, the bearing capacity is influenced by the presence of rigid walls confining the foundation soil. This problem is investigated within the framework of the theory of yield design, considering both a perfectly rough and a frictionless contact condition at the in
## a b s t r a c t In the present study, the effects of multiple-footing configurations in sand on bearing capacity were investigated using field plate load tests and finite element analyses. Both strip and spread footings were considered in the finite element analyses. In each case, different foo
This paper describes a technique for computing lower bound limit bearing capacity of rectangular surface footings. A perfectly rigid plastic model is adopted to describe the property of soil materials. The bearing capacity of footing is regarded as the objective function in this method, subject to t